background image

  

OPERATION MANUAL  

SUMMARIZE 

 

The instrument is a stable digital multimeter driven by battery. It comes 

with 20mm high LCD to make reading more clear. Backlight display and 
overload protection make it convenient to use .This instrument features multi 
functions for measuring DCV, ACV, DCA,ACA, resistance, capacitance, 

diode, continuity and frequency

.

, The instrument utilizes a dual-integral A/D 

converter as a key feature and is an excellent tool. It is portable and Ideal for 
lab, factory and field use.  

 

 

SAFETY NOTE 

 

The meter meets the standards of IEC1010.   
Please read the operation manual carefully before operation.  
1

 Do not input anything over a range limit.  

2

 Voltage below 36V is safe. To avoid electric shock, check whether the test 

leads  are  connected  correctly,  whether  the  insulation  is  good  when 
measuring over 36DCV or 25ACV.  

3

 Remove the test leads when changing function and range.  

4

  To  select  correct  function  and  range,  make  sure  the  range  limit  setting  is 

correct.  Start with higher limits and work down to correct level if uncertain.  

5

 Do not operate the meter if battery case and back cover is not properly fixed.  

6

 Do not input voltage when measuring resistance.  

7

  Remove  test  leads  from  test  point  and  turn  off  the  power  before  replacing 

battery and fuse.  

8

 SAFETY SYMBOLS  

 

“ 

”DANGEROUS VOLTAGE EXISTS

  

 

“  ”  GND

”DUAL INSULATION  

 

“ 

”THE OPERATOR MUST REFER TO THE MANUAL 

  

“”LOW BATTERY  

  

CHARACTERISTIC 1 

GENERAL 

 

1.1 Display:

 

LCD displaying.  

1.2 Max. displaying: 1999

3 1/2digit

auto polarity indication.  

1.3 Measuring method: dual slope A/D conversion.  
1.4 Sampling rate: approx. 3 times/second.  
1.5 Over range indication: the MSD displays

 

“OL”.  

1.6 Low battery indication:“

” appears.  

Summary of Contents for MT-1705

Page 1: ...MT 1705 3 1 2 True RMS Multimeter User s Manual 1st Edition 2014 Copyright by Prokit s Industries Co Ltd...

Page 2: ...t leads are connected correctly whether the insulation is good when measuring over 36DCV or 25ACV 3 Remove the test leads when changing function and range 4 To select correct function and range make s...

Page 3: ...200mV 0 5 3 100uV 2V 1mV 20V 10mV 200V 100mV 600V 1 0 10 1V Input resistance All ranges 10 M Overload protection 250V DV or AC peak value at 200mV range 600V DC or AC peak value at other ranges 2 2 2...

Page 4: ...2 2 4 ACA True RMS measurement Range Accuracy Resolution 40Hz 200Hz 200Hz 1kHz 200mA 1 5 15 1 5 15 sine and triangular wave 8 0 15 other wave 100uA 10A 3 0 10 3 0 10 sine and triangular wave 10mA Max...

Page 5: ...RESOLUTION 20nF 3 5 20 10pF 200nF 100pF 2uF 1nF 20uF 5 0 10 10nF 200uF 100nF 2000uF 1uF Overload protection 250V DC or AC peak value NOTE when over range it can keep on measuring OL will not show on L...

Page 6: ...n and range 3 1 5 GND 3 1 6 10A current test jack 3 1 7 pole jack of voltage resistance diode capacitance and resistance 3 2 VOLTAGE MEASUREMENT 3 2 1 Insert the black test lead to COM jack the red on...

Page 7: ...range knob to a proper resistance range connect the test leads across to the resistance being measured NOTE a If the resistance value being measured exceeds the max value of the range selected LCD dis...

Page 8: ...less a reading is possible but maybe over range b Shielded cable is recommended when measuring small signals under noisy conditions c Be careful when measuring high volt circuit d Do not input a volta...

Page 9: ...meter and should only be serviced by factory personnel 4 1 Do not operate or store the instrument in high temperature or high humidity place and do not work closed to flammability substance or explosi...

Page 10: ...9 NO CURRENT INPUT Replace fuse BIG ERROR Replace battery PROKIT S INDUSTRIES CO LTD http www prokits com tw E mail pk mail prokits com tw 2014 Prokit s Industries Co LTD All rights reserved 2014001 C...

Reviews: