background image

temperature reading is higher than setting temperature 

8: Low temperature alarm: the alarm buzzer on when the 

temperature reading is lower than setting temperature 

9: Max measuring reading: it shows maximum temperature reading 

after pressing the measure button and hold for a while 

10: Min measuring reading: it shows minimum temperature reading 

after pressing the measure button and hold for a while 

11: Average measuring reading: it shows average temperature 

reading after pressing the measure button and hold for a while 

12: Difference measuring reading: it shows the difference between 

maximum and minimum reading 

13: Emissivity: adjustable from 0.1 to 1.0 to suitable for testing of 

different articles 

6. Infrared thermometer should be protected in the following:

--EMF (electro-magnetic fields) from arc welders, induction

heaters. 

--Thermal shock (caused by large or abrupt ambient temperature 

changes, it allows 30 minutes for unit to stabilize before use). 

--Do not leave the unit on or near objects of high 

temperature. 

7. Maintenance

1. Lens cleaning: use clean compressed air to blow off loose

particles, use a soft brush to remove debris, at last clean it with
wet cotton cloth.

2. Case cleaning: clean the case with a damp sponge/cloth and

mild soap.

NOTE: 
1. Do not use solvent to clean lens.
2. Do not submerge the unit in water

5

Summary of Contents for MT-4612

Page 1: ...MT 4612 INFRARED THERMOMETER User s Manual 1st Edition 2015 Copyright by Prokit s Industries Co Ltd 1 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Page 2: ...s at eye 2 Operation 1 Turn on Install the battery and press the measurement button then the thermometer will turn on and show the temperature reading automatically 2 LCD display The LCD will display...

Page 3: ...s critical make sure the target is at least twice as large as the spot size 4 Emissivity Most organic materials painted or oxidized surfaces have an emissivity of 0 95 pre set in the unit Inaccurate r...

Page 4: ...or switching between and 1 Data Hold to keep current reading 2 Laser Sign test with laser 3 Low Battery Indication to remind user to change battery 4 Data recall press the function key to display the...

Page 5: ...hows the difference between maximum and minimum reading 13 Emissivity adjustable from 0 1 to 1 0 to suitable for testing of different articles 6 Infrared thermometer should be protected in the followi...

Page 6: ...0 0 90 Cement 0 96 Asbestos 0 95 Soil 0 90 0 98 Plaster 0 80 0 90 Mortar 0 89 0 91 Asphalt 0 95 Brick 0 90 0 96 Rock 0 7 Marble 0 94 Wood 0 90 0 95 Textile 0 90 Charcoal powdered 0 96 Paper 0 95 Carbo...

Page 7: ...MT 4612 1 2 3 0 5 4 15 7...

Page 8: ...6 5 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 4 3 8...

Page 9: ...1 2 3 4 MODE 2 3 0 5 MODE 5 6 7 HAL 8 LAL 9 MAX 10 MIN 11 AVG 12 DIF 13 EMS 14 MODE 9 20 50 0 5 2 2 16 1 50 580 58 1076 9...

Page 10: ...2 or 2 0 1 0 1 0 5S 0 1 1 9 20 to 50 4 122 0 to 50 32 122 10 95 RH 9V 0 1 1 0 0 1 1 0 D S 36cm 22 5mm 3 3 10...

Page 11: ...1 2 3 4 5 6 7 1 2 2 0 3 0 3 11...

Page 12: ...0 7 0 94 0 90 0 95 0 90 0 96 0 95 0 85 0 90 0 97 0 92 0 96 0 90 0 9 0 75 0 80 0 85 0 92 0 93 0 95 0 83 0 90 0 95 0 96 0 98 0 95 0 95 0 94 0 95 0 80 0 98 0 94 0 93 0 5 PROKIT S INDUSTRIES CO LTD 2015...

Reviews: