Figure 8 Front panel of PM235
9
Table 5 Connection of PM235
CATEGORY
QTY
DESCRIPTION
POSSIBLE LOAD SUITABLE
Class A1
1
Relay controlled output with fuse, protected by main master switch relay
Water pump
Class B
10
Fused outputs, protected by master switch relay
Ventilation fan etc
Class C
2
Live load
Fridge, security alarm etc.
Class D
1
Permanent on load
Auto step
N
O
LABEL
DEFINITION
DESCRIPTION
1
AC Mains
AC input port
2
Switch panel
Comm port
Connect to switch panel
3
LCD Display
Comm port
Connect to monitor
(Monitor is not available in PM200)
4
Battery switch
Service battery switch
Manual battery switch
5
Fresh water tank 1
Connect to fresh water tank 1
6
Fresh water tank 2
Fresh water tank 2 is not available in PM200
7
Tap water tank
Connect to tap water tank
8
Waste water tank
Connect to waste water tank
9
Battery sensor
For temp compensation
Connect to service
10 PV+
Solar input
Connect to PV+
11 PV-
Solar input
Connect to PV-
12 Starter Bat+
Starter
Connect to starter
13 Service Bat+
Service
Connect to service
14 Starter Bat-
Starter battery-
Connect to starter battery-
15 Service Bat-
Service battery-
Connect to service battery-
16 L1+
Step
Connect to load of class D
17 L2+ ~ L3+
Connect to load of class C
18 L4+ ~ L10+
Connect to load of class B
19 L11+
Water pump
Connect to Water pump+
20
L12+ ~ L14+
Connect to load of class B
21 L1- ~ L14-
Connect to DC load -
22 D+ Point
D+ input
Connect to D+
23 Remote Switch
Terminal block
Connect to remote switch
24 Select Switch
Dip switch
Select local switch or remote switch
(Note: open the upper cover board to operate)
25 Setting
Dip switch
Set the battery type and capacity
(Note: open the upper cover board to operate)
26 Fuse
Fuses and fuse failure indication
3. STRUCTURE AND INSTALLATION
3.1 PM200 Master Power Unit