Projecta INTELLI JAY PM100-BTJ Manual Download Page 8

3. Operation

3.1  Configuration

SIDE PANEL

3.2 Wiring

WIRING SIZE:

DC cables must be sized to carry the maximum full load current and not to exceed the 

system volt drop requirements. The following cable sizes are recommended. When running 
wires, if they pass through panels or wall, ensure the wires are protected from damage by 

sharp edges. The use of additional cable insulation or tubing is recommended.

No.

LABEL

DEFINITION

DESCRIPTION

1

Power

AC cable

Kettle /computer/IEC type plug

2

RS485

Communication

Connect to PMBTJ-02

3

Load Switch

Low power consumption

Connect external switch

4

Vehicle Bat+

Vehicle battery terminal

Connect to vehicle

5

Vehicle Bat-

Connect to vehicle battery-

6

House Bat+

House battery terminal

Connect to house

7

House Bat+

Connect to house battery-

8

Load+

Centralised output connect

Connect to high output load+

9

Load-

Connect to high output load-

10

L1+ 

 L8+

Separated DC outputs connector

Connect to DC load+

11

L9+

Connect to DC load+

12

L10+

Connect to DC load+

13

L10-

Connect to DC load-

14

L9-

Connect to DC load-

15

L8-

 L1-

Connect to DC load-

CURRENT

MINIMUM CABLE SIZE

0-5A

1.0mm or 18 AWG

5-10A

2.0mm or 14AWG

10-15A

3.0mm or 13AWG

15-20A

4.0mm or 11AWG

20-25A

5.0mm or 10AWG

25-35A

6.0mm or 9 AWG

1

2

3 4 5 6 7 8 9

10

11121314

15

Summary of Contents for INTELLI JAY PM100-BTJ

Page 1: ...12V POWER MANAGEMENT SYSTEM P No PM100 BTJ PM100J Transformer Unit WSM 3 Water Sensor Module PMBTJ 02 Bluetooth Node Phone App Need technical help Contact Projecta on 1800 294 294 INTELLI...

Page 2: ...nection to supply mains is to be in accordance with national wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If theAC cord is damaged do not attempt to u...

Page 3: ...ection 5 1 4 Voltage charging relay VCR 5 1 5 Specification 6 2 STRUCTURE 7 3 OPERATION 8 3 1 Configuration 8 3 2 Wiring 8 3 3 LED diagnostic codes 9 3 4 Connecting to a Smart Device Bluetooth 10 3 5...

Page 4: ...AINS MULTIPLE CHARGING INPUTS The PM100 BTJ has two inputs AC mains and vehicle battery Only one source will provide power at a time with priority given toAC mains if available 15A 15A 10A 10A AC DC V...

Page 5: ...e maintains the battery at 100 charge RECYCLE Restarts the charge every 10 days 3 4 5 11 5V lcc 1 2 lcc POWER SUPPLY MODE The PM100J transformer will automatically switch between power supply and char...

Page 6: ...4 14 7VDC Gel AGM LFP Wet Float voltage 13 5 13 5 13 5 13 8VDC Gel AGM LFP Wet Power Supply Mode AC Charging Norminal output voltage 12 8 0 2 VDC Rated output current 35A Continuous Efficiency 88 Work...

Page 7: ...7 2 Structure 133 4 13 3 43 2 161 3 151 6 5 11 60 82 4 6 43 2 196 9 120 38 5 4 5 260 270 70 250 79 5 5 50 55 55 80 PM100J Transformer Unit WSM 3 Water Sensor Module PMBTJ 02 Bluetooth Node...

Page 8: ...tch Low power consumption Connect external switch 4 Vehicle Bat Vehicle battery terminal Connect to vehicle battery 5 Vehicle Bat Connect to vehicle battery 6 House Bat House battery terminal Connect...

Page 9: ...meet the requirements VCR disconnected OFF No vehicle battery connected 3 Charge Green ON Battery is fully charged or in floating phase Flashing flash once every second Battery is charging Slow flashi...

Page 10: ...ode When this node shows up in the device list tap and you will be prompted to enter a pairing code 4 The default pairing code Is the last four 4 digits of your PMBTJ 02 node s serial number You can f...

Page 11: ...the system and do not disconnect power to the system or your phone during an update 4 From the home screen the PM100 BTJ app allows the user to remotely monitor key aspects of the power system from th...

Page 12: ...ery connected Absorption charging by Mains Grid Charge flashes once every sec Vehicle battery connected Absorption charging by Mains Grid Floating charge by Mains Grid No vehicle battery connected Flo...

Page 13: ...t over temp alarm PM100J is working under PS mode PM100J will restart automatically FAULT flashes 3 times every cycle Charge flashes as 1 sec on then 2 sec off PM100J unit over temp alarm PM100J is wo...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...of purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to rep...

Reviews: