Projecta INTELLI JAY PM100-BTJ Manual Download Page 6

1.5  Specification

MODEL

PM100J

ELECTRICAL SPECIFICATIONS

Mains

Nominal input voltage (V)

240±10%VAC 50/60Hz

Power factor

0.95

Input current at full load

2.5A

Battery

Vehicle battery

12VDC

Vehicle battery voltage range

12.8-16VDC

House battery

12VDC

House battery voltage range

10.5-16VDC

Voltage Sensitive Relay

Relay specification

12Vdc 60A Continuous, Peak current 100A, 30min

Connect voltage

13.4V (Lead Acid) / 13.7V (Lithium)

Connection delay time

10 sec

Disconnect voltage

12.8V (Lead Acid) / 13.3V & <2A (Lithium)

Disconnect delay time

60 sec

High voltage limit

16.0VDC

House battery charger Charge /
Power Supply switch set to OFF

Charge Algorithms

5 steps, soft start, bulk, absorption, float, recycle

Battery type

AGM, GEL, WET, LiFePO

4

Start Voltage

2VDC (lead acid), 0VDC (lithium)

Bulk current 

30A

Absorption Voltage

 14.1/14.4/14.4/14.7VDC (Gel/AGM/LFP/Wet)

Float voltage

 13.5/13.5/13.5/13.8VDC (Gel/AGM/LFP/Wet)

Power Supply Mode 

 

AC Charging

Norminal output voltage

12.8±0.2 VDC

Rated output current

35A (Continuous)

Efficiency

88%

Working temperature

-40°C~+65°C 

 

(50°C: full load; 60°C:20A; 65°C: shutdown the output)

OTHERS

Battery Disconnect (LVD)

Disconnect voltage

10.5VDC (lead acid), 11.2VDC (lithium)

Delay off time

60 sec

Reconnect voltage

11.5VDC (lead acid), 12.2VDC (lithium)

Current draw on Battery

240VAC is off, no vehicle charging

200mA

When battery disconnected by LVD

60mA

When insufficient voltage available

When remote switch is turn off = 0mA

Fused outputs

Rated Current

8 x 10A + 2 x 15A

Protection

Short circuit on output

Fuse protected

Reverse polarity

Overload protection
Battery charger over temperature

Automatic Shutdown

Battery over voltage limits

PHYSICAL SPECIFICATIONS

Dimensions  (L*W*H)

270 x 197 x 70mm

Weight (kg)

2.6kgs

Enclosure

Steel Case

Battery terminals

M4 Screw (16mm

2

)

Load terminals

M3 Screw (4mm

2

), M3.5 Screw (6mm

2

)

Cooling

Automatic fan

Summary of Contents for INTELLI JAY PM100-BTJ

Page 1: ...12V POWER MANAGEMENT SYSTEM P No PM100 BTJ PM100J Transformer Unit WSM 3 Water Sensor Module PMBTJ 02 Bluetooth Node Phone App Need technical help Contact Projecta on 1800 294 294 INTELLI...

Page 2: ...nection to supply mains is to be in accordance with national wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If theAC cord is damaged do not attempt to u...

Page 3: ...ection 5 1 4 Voltage charging relay VCR 5 1 5 Specification 6 2 STRUCTURE 7 3 OPERATION 8 3 1 Configuration 8 3 2 Wiring 8 3 3 LED diagnostic codes 9 3 4 Connecting to a Smart Device Bluetooth 10 3 5...

Page 4: ...AINS MULTIPLE CHARGING INPUTS The PM100 BTJ has two inputs AC mains and vehicle battery Only one source will provide power at a time with priority given toAC mains if available 15A 15A 10A 10A AC DC V...

Page 5: ...e maintains the battery at 100 charge RECYCLE Restarts the charge every 10 days 3 4 5 11 5V lcc 1 2 lcc POWER SUPPLY MODE The PM100J transformer will automatically switch between power supply and char...

Page 6: ...4 14 7VDC Gel AGM LFP Wet Float voltage 13 5 13 5 13 5 13 8VDC Gel AGM LFP Wet Power Supply Mode AC Charging Norminal output voltage 12 8 0 2 VDC Rated output current 35A Continuous Efficiency 88 Work...

Page 7: ...7 2 Structure 133 4 13 3 43 2 161 3 151 6 5 11 60 82 4 6 43 2 196 9 120 38 5 4 5 260 270 70 250 79 5 5 50 55 55 80 PM100J Transformer Unit WSM 3 Water Sensor Module PMBTJ 02 Bluetooth Node...

Page 8: ...tch Low power consumption Connect external switch 4 Vehicle Bat Vehicle battery terminal Connect to vehicle battery 5 Vehicle Bat Connect to vehicle battery 6 House Bat House battery terminal Connect...

Page 9: ...meet the requirements VCR disconnected OFF No vehicle battery connected 3 Charge Green ON Battery is fully charged or in floating phase Flashing flash once every second Battery is charging Slow flashi...

Page 10: ...ode When this node shows up in the device list tap and you will be prompted to enter a pairing code 4 The default pairing code Is the last four 4 digits of your PMBTJ 02 node s serial number You can f...

Page 11: ...the system and do not disconnect power to the system or your phone during an update 4 From the home screen the PM100 BTJ app allows the user to remotely monitor key aspects of the power system from th...

Page 12: ...ery connected Absorption charging by Mains Grid Charge flashes once every sec Vehicle battery connected Absorption charging by Mains Grid Floating charge by Mains Grid No vehicle battery connected Flo...

Page 13: ...t over temp alarm PM100J is working under PS mode PM100J will restart automatically FAULT flashes 3 times every cycle Charge flashes as 1 sec on then 2 sec off PM100J unit over temp alarm PM100J is wo...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...of purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to rep...

Reviews: