Projecta IC2500 User Manual Download Page 24

WARRANTY STATEMENT

Applicable only to product sold in Australia

Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic., 
telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in 
its current catalogue (save and except for all bulbs and lenses whether made of glass or 
some other substance) will under normal use and service be free of failures in material and 
workmanship for a period of one (1) year (unless this period has been extended as indicated 
elsewhere) from the date of the original purchase by the consumer as marked on the 
invoice. This warranty does not cover ordinary wear and tear, abuse, alteration of products 
or damage caused by the consumer. 
To make a warranty claim the consumer must deliver the product at their cost to the 
original place of purchase or to any other place which may be nominated by either BWI or 
the retailer from where the product was bought in order that a warranty assessment may 
be performed. The consumer must also deliver the original invoice evidencing the date and 
place of purchase together with an explanation in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the product then 
BWI reserves the right to repair or replace it at its discretion. In the event that a major 
failure is determined the consumer will be entitled to a replacement or a refund as well as 
compensation for any other reasonably foreseeable loss or damage.
This warranty is in addition to any other rights or remedies that the consumer may have 
under State or Federal legislation.

IMPORTANT NOTE

Our goods come with guarantees that cannot be excluded under the Australian Consumer 
Law. You are entitled to a replacement or refund for a major failure and compensation for 
any other reasonably  foreseeable loss or damage. You are also entitled to have the goods 
repaired or replaced if the goods fail to be of acceptable quality and the failure does not 
amount to a major failure.

Distributed by

AUSTRALIA
Brown & Watson International Pty Ltd

Knoxfield, Victoria 3180
Telephone  (03) 9730 6000
Facsimile  (03) 9730 6050
National Toll Free  1800 113 443 

NEW ZEALAND
Narva New Zealand Ltd

22–24 Olive Road
PO Box 12556 Penrose
Auckland, New Zealand
Telephone  (09) 525 4575
Facsimile 

(09) 579 1192

IS155

Issue 4 19.07.12

Summary of Contents for IC2500

Page 1: ...INTELLI CHARGE 7 STAGE SWITCHMODE BATTERY CHARGER P No s IC2500 IC2500W IC3500 IC5000 IC800 24...

Page 2: ...rdance with National wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If the AC cord is damaged do not attempt to use It must be replaced or repaired by a...

Page 3: ...ging time by delivering maximum charge to set voltage 4 ABSORPTION Ensures a full charge to the battery without overcharging EQUALISATION Calcium mode only Returns a full hydrometer reading to calcium...

Page 4: ...er will apply a recondition charge to try to return the battery to full charge RECONDITION If after charging the battery is unable to hold the charge the battery reconditioning function is initiated a...

Page 5: ...and has a maximum charge voltage of 14 1V Note that some GEL batteries require a higher charge voltage such as 14 4V The AGM mode can be used if this is required AGM MAX VOLTAGE OF 14 4 VOLTS This ch...

Page 6: ...to prevent overcharging This is ideal for batteries used in warmer climates or environments SWITCHMODE TECHNOLOGY LCD SCREEN LED INDICATORS POLARITY PROTECTION OVER TEMPERATURE PROTECTION MOUNTING IN...

Page 7: ...to the mounting surface as per the below illustration Drill a 15mm cable exit hole into the mounting surface ensure cable exit hole is positioned directly in the middle of the mounting plate Position...

Page 8: ...RGE POWER ON POWER ON FULLY CHARGED RECON CHARGE BAT TYPE VOLT AMP ABSORB POWER ON BULK CHARGE FULLY CHARGED RECON CHARGE BAT TYPE VOLT AMP ABSORB POW POWER ON CHARGE BAT TYP VOLT AMP POWER ON BULK CH...

Page 9: ...settings to best suit your battery The function of each button is explained below 1 VOLT AMP Change LCD screen display from battery voltage to input current 2 CHARGE RATE Set the charge rate to suit t...

Page 10: ...harging LED LED SIGNAL STAGES OF CHARGING Desulphation Soft Start Bulk Absorption Analysis Recondition Float Equalisation Bulk Charge Fast Flash Slow Flash Solid On Slow Flash Blue Absorption Solid On...

Page 11: ...TERY There are three options for connecting to battery Step 2A Connecting to a battery that is out of the vehicle Step 2B Connecting to a battery fitted to a vehicle Step 2C Permanent hard wiring conn...

Page 12: ...7 Stage POWER ON BULK CHARGE ABSORPTION FULLY CHARGED VOLTS AMPS CHARGE RATE BATTERYTYPE RECONDITION ON OFF Connection in vehicle negatively earthed STEP 2B BATTERY IN VEHICLE Determine if the vehicl...

Page 13: ...he DC leads are cut ensure that the sensor wires are included in both positive and negative connections 2 Connect a circuit breaker or inline fuse to the RED Positive lead include sensor wire if DC le...

Page 14: ...Cable length 4 5 metres Warning Ensure the cable is secured safely away from moving parts Installing Temperature Sensor To install the temperature sensor insert the plug into the temperature sensor s...

Page 15: ...500 1000 3000 1400 4200 7 24 35 Amp 240 700 1440 4200 2000 5800 7 24 50 Amp 350 1000 2100 6000 2900 8300 7 24 ADJUSTABLE CHARGE RATES 24 VOLT BATTERIES CHARGE RATE BATTERY SIZE 24V Deep Cycle AH Autom...

Page 16: ...green FULLY CHARGED LED will illuminate This is known as the float stage and the charger can be left connected to the battery without over charging If the red POWER LED is flashing or the LCD screen d...

Page 17: ...tion the LCD screen will display rapid horizontal lines Upon completion of the recondition the charger will proceed to carry out a normal charge on the battery STEP 3 Follow STEPS 7 to 9 of the Chargi...

Page 18: ...The charger has entered recondition mode 3 times and has timed out Battery may be faulty and may need replacing OR There is a load on the battery causing the battery to fail Analysis OTP Fast Flashin...

Page 19: ...12 Amp setting 1 8A 6 Amp setting 0 9A 25 Amp setting 3 75A 35 Amp setting 5 25A 25 Amp setting 3 75A 8 Amp setting 1 2A 50 Amp setting 7 5A Equalization Constant current Constant current Constant cur...

Page 20: ...SORPTION FULLY CHARGED TEMPERATURE SENSOR REMOTE ON VOLTS AMPS CHARGE RATE BATTERY TYPE RECONDITION OFF 12V 35A 7 Stage POWER ON BULK CHARGE ABSORPTION FULLY CHARGED TEMPERATURE SENSOR REMOTE ON VOLTS...

Page 21: ...arger can then start to charge the battery and the booster cables can be removed Q Can I use the charger as a power supply A Power Supply mode is designed to operate as a float charge to maintain a ba...

Page 22: ...alled Equalisation This consists of a constant current being fed into the battery until 16 Volts 12V or 32 Volts 24V is reached This rejuvenates the battery cells This charging stage can take up to 12...

Page 23: ...23 NOTES...

Page 24: ...rchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or...

Reviews: