Projecta IC2500 User Manual Download Page 22

22

Q. What if I have an appliance connected to the battery whilst charging?

A. Powering an appliance while charging your battery will impact on the battery chargers 

ability to accurately measure the battery’s response to the charge being applied.  
The battery charger has been designed to accommodate this situation although not 
recommended.

  For optimum charging it is recommended to charge without any appliance load on  

the battery. Power Supply mode is recommended when an appliance is connected to  
a battery and is drawing power.

Q. Can I select a different battery chemistry for charging my battery?

A. Yes the battery chemistry selection can be different to your battery type if the charge 

voltages match the battery manufacture’s recommendations. 

Q. Why does CALCIUM mode take so long to charge?

A. To fully charge a Calcium battery, the battery requires an extra charging stage called 

‘Equalisation’. This consists of a constant current being fed into the battery until 
16 Volts (12V) or 32 Volts (24V) is reached. This rejuvenates the battery cells. This 
charging stage can take up to 12 hours.

Q. Why do I need a special Calcium mode?

A. Because of the different chemistry used to make a Calcium battery, a different charging 

algorithm (or technique) is required. Calcium batteries are also affected when deeply 
discharged or used heavily. They need to be recharged by a Calcium charger to fully 
recharge the battery and to maximize the battery’s life and performance.

Q. What is a Calcium battery?

A. Calcium batteries are lead acid batteries that have had calcium added to the  

lead plates, either to one plate (called Calcium Hybrid) or to both plates (called 
Calcium–Calcium). 
The added calcium provides a number of benefits:
i.  Lower internal resistance which provides a small increase in CCA performance.
ii.  The ability to withstand higher engine bay temperatures.
iii. Low self discharge rate, which increases the shelf life, typically 4 times longer  

than a Lead–Lead battery.

Summary of Contents for IC2500

Page 1: ...INTELLI CHARGE 7 STAGE SWITCHMODE BATTERY CHARGER P No s IC2500 IC2500W IC3500 IC5000 IC800 24...

Page 2: ...rdance with National wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If the AC cord is damaged do not attempt to use It must be replaced or repaired by a...

Page 3: ...ging time by delivering maximum charge to set voltage 4 ABSORPTION Ensures a full charge to the battery without overcharging EQUALISATION Calcium mode only Returns a full hydrometer reading to calcium...

Page 4: ...er will apply a recondition charge to try to return the battery to full charge RECONDITION If after charging the battery is unable to hold the charge the battery reconditioning function is initiated a...

Page 5: ...and has a maximum charge voltage of 14 1V Note that some GEL batteries require a higher charge voltage such as 14 4V The AGM mode can be used if this is required AGM MAX VOLTAGE OF 14 4 VOLTS This ch...

Page 6: ...to prevent overcharging This is ideal for batteries used in warmer climates or environments SWITCHMODE TECHNOLOGY LCD SCREEN LED INDICATORS POLARITY PROTECTION OVER TEMPERATURE PROTECTION MOUNTING IN...

Page 7: ...to the mounting surface as per the below illustration Drill a 15mm cable exit hole into the mounting surface ensure cable exit hole is positioned directly in the middle of the mounting plate Position...

Page 8: ...RGE POWER ON POWER ON FULLY CHARGED RECON CHARGE BAT TYPE VOLT AMP ABSORB POWER ON BULK CHARGE FULLY CHARGED RECON CHARGE BAT TYPE VOLT AMP ABSORB POW POWER ON CHARGE BAT TYP VOLT AMP POWER ON BULK CH...

Page 9: ...settings to best suit your battery The function of each button is explained below 1 VOLT AMP Change LCD screen display from battery voltage to input current 2 CHARGE RATE Set the charge rate to suit t...

Page 10: ...harging LED LED SIGNAL STAGES OF CHARGING Desulphation Soft Start Bulk Absorption Analysis Recondition Float Equalisation Bulk Charge Fast Flash Slow Flash Solid On Slow Flash Blue Absorption Solid On...

Page 11: ...TERY There are three options for connecting to battery Step 2A Connecting to a battery that is out of the vehicle Step 2B Connecting to a battery fitted to a vehicle Step 2C Permanent hard wiring conn...

Page 12: ...7 Stage POWER ON BULK CHARGE ABSORPTION FULLY CHARGED VOLTS AMPS CHARGE RATE BATTERYTYPE RECONDITION ON OFF Connection in vehicle negatively earthed STEP 2B BATTERY IN VEHICLE Determine if the vehicl...

Page 13: ...he DC leads are cut ensure that the sensor wires are included in both positive and negative connections 2 Connect a circuit breaker or inline fuse to the RED Positive lead include sensor wire if DC le...

Page 14: ...Cable length 4 5 metres Warning Ensure the cable is secured safely away from moving parts Installing Temperature Sensor To install the temperature sensor insert the plug into the temperature sensor s...

Page 15: ...500 1000 3000 1400 4200 7 24 35 Amp 240 700 1440 4200 2000 5800 7 24 50 Amp 350 1000 2100 6000 2900 8300 7 24 ADJUSTABLE CHARGE RATES 24 VOLT BATTERIES CHARGE RATE BATTERY SIZE 24V Deep Cycle AH Autom...

Page 16: ...green FULLY CHARGED LED will illuminate This is known as the float stage and the charger can be left connected to the battery without over charging If the red POWER LED is flashing or the LCD screen d...

Page 17: ...tion the LCD screen will display rapid horizontal lines Upon completion of the recondition the charger will proceed to carry out a normal charge on the battery STEP 3 Follow STEPS 7 to 9 of the Chargi...

Page 18: ...The charger has entered recondition mode 3 times and has timed out Battery may be faulty and may need replacing OR There is a load on the battery causing the battery to fail Analysis OTP Fast Flashin...

Page 19: ...12 Amp setting 1 8A 6 Amp setting 0 9A 25 Amp setting 3 75A 35 Amp setting 5 25A 25 Amp setting 3 75A 8 Amp setting 1 2A 50 Amp setting 7 5A Equalization Constant current Constant current Constant cur...

Page 20: ...SORPTION FULLY CHARGED TEMPERATURE SENSOR REMOTE ON VOLTS AMPS CHARGE RATE BATTERY TYPE RECONDITION OFF 12V 35A 7 Stage POWER ON BULK CHARGE ABSORPTION FULLY CHARGED TEMPERATURE SENSOR REMOTE ON VOLTS...

Page 21: ...arger can then start to charge the battery and the booster cables can be removed Q Can I use the charger as a power supply A Power Supply mode is designed to operate as a float charge to maintain a ba...

Page 22: ...alled Equalisation This consists of a constant current being fed into the battery until 16 Volts 12V or 32 Volts 24V is reached This rejuvenates the battery cells This charging stage can take up to 12...

Page 23: ...23 NOTES...

Page 24: ...rchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or...

Reviews: