![Projecta HDBM4000 Instruction Manual Download Page 20](http://html1.mh-extra.com/html/projecta/hdbm4000/hdbm4000_instruction-manual_1614103020.webp)
20
ATTENTION! Pay special attention to the type of battery being equalized
(WET, GEL, AGM, PbCa): check the maximum allowed voltage to avoid
damaging the same.
Customising the VOLTAGE
To customise the equalization voltage value simultaneously press and hold the
“BATTERY VOLTAGE” (fig. A.21) and “MODE” (fig. A.22) buttons for 3 seconds,
then use the same buttons to select (decrease using the “BATTERYVOLTAGE”
button and increase using the “MODE” button), the desired voltage value between
6V-8.0V, 12V-16V, 24V-32V respectively for 6V, 12V, 24V batteries.
The factory default voltage value is respectively 6.8V, 13.6V, 27.2V.
The set voltage mode will be exited automatically after a 3” time-out.
Procedure
– press the “MODE” button (fig. A.22) to select this function (fig. A.9);
– press the “BATTERY VOLTAGE” button (fig. A.21) to select the battery voltage
(fig. A.1);
– connect the clamps to the battery terminals;
– the equalization process will run automatically indicating the voltage value on
the display (fig.A.2), along with the current (fig. A.4) output. On completing the
process, the word “End” will appear on the display (fig. A.2).
BEEP
Info
Alarm
DISPLAY
3"
BEEP
DISPLAY
13.3V
13.2V
13.1V
. . . . .
. . . . .
13.7V
13.6V
13.5V
MODE
MODE
BATTERY VOLTAGE
END OF PROCESS – EXAMPLE
FUNCTION SELECTION
VOLTAGE ADJUSTMENT – EXAMPLE
BEEP
Info
Alarm
MODE
BATTERY
VOLTAGE
CHARGE
RATE
BATTERY
VOLTAGE
CHARGE
RATE
END OF PROCESS – EXAMPLE
ADVANCED MENU SELECTION
KEYBOARD LOCK
KEYBOARD UNLOCK
3"
BEEP
MENU
ADVANCED
PROGRAMS
3
DISPLAY
3
DISPLAY