PROGTECH Lighting SAFE 40 User Manual Download Page 3

WARNINGS

Following  instructions  must  be  consulted  in  order  to  obtain  a  correct 

installation, use and maintenance of product, as well as ensuring your safety.

Still retain this documentation for future reference, even for those who will 

later work on the lamp for any reason.

FEATURES

Industrial  LED  projector  made  with  aluminum  structure  and  heatsink, 

painted steel brackets and a glass lens. The overall dimensions is 210 mm 

(L) x 210mm (W) x 280mm (H)

• 

LED light source

• 

LED Colour RED or GREEN

• 

Absorption MAX 0,15A (RED SAFE 40), 0,18A (GREEN SAFE 40)

• 

Frequency: 50-60 Hz

• 

Input voltage From 90Vac to 305Vac

• 

Consumption 40W (GREEN SAFE), 32W (RED SAFE 40)

• 

Appliance with isolation class I

• 

Max nominal ambient temperature: +60°C (GREEN SAFE 40), +50°C (RED 

SAFE 40)

• 

Min nominal ambient temperature: -30°C

• 

IP Protection class: IP64

• 

Use of heat-resistant power cables, interconnection cables or external wiring 

till +90°C

SAFETY RULES

Always switch off the fixture before carrying out any cleaning.

Before taking any action on it make sure it has completely cooled.

Fixture suitable for installation on normally inflammable surfaces.

Designed for direct illumination of horizontal and vertical surfaces.

Appliance not suitable for direct mounting on surfaces normally flammable 

(suitable only for surfaces noncombustible).

Power cables, interconnection cables or external wiring heat resistant.

LED light source: it is recommended not to fix the beam to avoid possible 

permanent damage to the retina.

Device with protection degree IP64 for indoor and outdoor use. The lamps of 

this device are not substitutable.

Electrical part consists of a stabilized power supply: builtin protection circuit 

shuts  down  the  device  in  case  of  open  circuit,  short  circuit,  overload  or 

overheating; the power supply may not be turned on even after the fault. In 

this case, contact the manufacturer.

Conductor cross section min. 1 mmq.

Operating  temperature:  min.  -30°C  max.  +60°C  (GREEN  SAFE  40),  +50°C 

(RED SAFE 40).

The luminaire must be positioned in such a way that a prolonged observation 

of the luminaire is not possible at a distance of less than 4 meters.

Notes for the disposal of the device, see WEEE standards.

HOW TO USE

Open the box, extract the fixture carefully and store up the packaging.

After attaching the lamp using the hook (or the bracket, available on request), 

connect the power cord.

The lamp has a 3x1mmq three-core cable at the output, to be connected to 

the power supply (220Vac). The connection must made in order to maintain 

the IP64 degree of protection of the appliance.

Do not cover the device with plastic sheets, cloths, tissues cause it has to 

dissipate the heat produced by the light source.

For cleaning and maintenance always use a damp cloth without any solvents 

or acids.

For your safety, do not attempt to modify the unit.

The information contained in the following documents are subject to change 

without any notice by the company.

The company guarantees the conformity of the products with the applicable 

European safety and EMC.

We accept no responsibility for any damage to the product, to things and/or 

people, due to improper installation and/or because of changes made to the 

device,  using  accessories  and/or  electrical/electronic  components  are  not 

suitable.

It’s  strictly  forbidden  any  reproduction,  even  partial,  of  the  information 

contained in this leaflet.

Summary of Contents for SAFE 40

Page 1: ...MANUALE D USO USER MANUAL SAFE 40 ...

Page 2: ... Le lampade di questo dispositivo non sono sostituibili Sezione conduttori di alimentazione min 1mmq Temperatura di esercizio min 30 C max 60 C GREEN SAFE 40 50 C RED SAFE 40 L apparecchio di illuminazione deve essere posizionato in modo che non sia prevista un osservazione prolungata dell apparecchio ad una distanza inferiore ai 4mt Note per lo smaltimento dell apparecchio vedi norme RAEE UTILIZZ...

Page 3: ...t substitutable Electrical part consists of a stabilized power supply builtin protection circuit shuts down the device in case of open circuit short circuit overload or overheating the power supply may not be turned on even after the fault In this case contact the manufacturer Conductor cross section min 1 mmq Operating temperature min 30 C max 60 C GREEN SAFE 40 50 C RED SAFE 40 The luminaire mus...

Page 4: ... Parliament and the Council of the Europen Union Apparecchio che può essere installato su superfici normalmente infiammabili Temperatura di funzionamento normale non superiore a 90 C Temperatura di funzionamento in caso di guasto non superiore a 130 C EN 60598 1 ED 2000 A11 2000 A12 2002 A1 2006 Fixture suitable for direct mounting on normally inflammable surfaces Normal operating temperature not ...

Page 5: ...gio diretto su superfici normalmente infiammabili idonei solo al montaggio su superfici non combustibili Appliance not suitable for direct mounting on surfaces normally flammable suitable only for surfaces non combustible Uso di cavi di alimentazione di interconnessione o di cablaggio esterno resistenti al calore Power cables interconnection cables or external wiring heat resistant Alimentazione i...

Page 6: ...nte a quanto previsto nelle Condizioni di Garanzia ricevute al momento dell acquisto e alle schede tecniche consultabili sul sito www progtech it Grazie per il vostro acquisto WARRANTY This is to certify that the product purchased has been made entirely in Italy by CABLOTECH using high quality materials and with the aid of specialized manufacturing it was finally subjected to a careful process of ...

Page 7: ...PROGTECH srl via Milano 60 24040 Bonate Sopra Bg T 39 035 04 46 251 info progtech it www progtech it ...

Reviews: