Consult a licensed electrician or RV technician for installation assistance
INSTALLATION INSTRUCTIONS
WARNING:
TORQUE ALL CONNECTIONS PER LABEL – EXCESSIVE TORQUE MAY CAUSE DAMAGE
TO CONNECTIONS LEADING TO A FIRE CAUSING PROPERTY DAMAGE, SERIOUS INJURY OR
DEATH.
WARNING:
SHOCK HAZARD - DUE TO THE HIGH VOLTAGES ASSOCIATED WITH ITS OPERATION
ONLY QUALIFIED SERVICE PERSONNEL SHOULD INSTALL OR TROUBLESHOOT THIS TRANSFER
SWITCH! ALL APPLICABLE CODES AND STANDARDS MUST BE MET WHEN INSTALLING THIS
DEVICE. SEE WIRING DIAGRAM INSIDE OF THE COVER AND ON THE BACK OF THIS PAGE.
IMPROPER HANDLING OR INSTALLATION MAY CAUSE SERIOUS INJURY OR DEATH.
WARNING:
THE 5200 & 5300 SERIES AUTOMATIC TRANSFER SWITCHES ARE NOT IGNITION
PROTECTED AND SHOULD NOT BE MOUNTED IN THE SAME COMPARTMENT AS BATTERIES OR
FLAMMABLE MATERIALS SUCH AS GASOLINE. DO NOT MOUNT THE TRANSFER SWITCH IN THE
GENERATOR OR LP GAS COMPARTMENT. A FIRE CAUSING PROPERTY DAMAGE SERIOUS INJURY
OR DEATH COULD RESULT!
THESE PRODUCTS ARE NOT DESIGNED FOR USE WITH 240 VOLT SINGLE LEG SUPPLIES.
APPLICATION OF VOLTAGES IN EXCESS OF 130 VOLTS FROM HOT TO NEUTRAL MAY CAUSE
PERMANENT DAMAGE TO THE UNIT.
The 5200 & 5300 Automatic Transfer Switches can be installed as shown in figures 1 and 2 provided there is room to route the shore
power, generator, and distribution connection wires. The 5200 & 5300 Automatic Transfer Switches including the Remote Display are
not suitable for outdoor locations and should be mounted in a protected area. We recommend that the transfer switch be mounted as
close to the shore power and generator power cords as practical to reduce voltage loss.
REFER TO WIRING DIAGRAMS LOCATED INSIDE THE COVER FOR ALL
CONNECTION INFORMATION AND TORQUE REQUIREMENTS.
PROPER MOUNTING CONFIGURATIONS:
OPTIONAL VOLTAGE SENSE CONNECTION:
(Used for Auto Generator Start)
For transfer switches supplied with the optional voltage sense PCB assembly, connect the ’16 VAC OUT’ connections to the ‘Shore
Power Present’ inputs of your generator control center. These connections do not have a polarity requirement. This output will be
16VAC whenever shore power is present.
Figure 1 – Horizontal Wall Mount
Figure 2 – Floor Mount