Consult a licensed electrician or RV technician for installation assistance 

INSTALLATION INSTRUCTIONS 

 

WARNING:

 TORQUE ALL CONNECTIONS PER LABEL – EXCESSIVE TORQUE MAY CAUSE DAMAGE 

TO CONNECTIONS LEADING TO A FIRE CAUSING PROPERTY DAMAGE, SERIOUS INJURY OR 

DEATH. 

 

WARNING:

 SHOCK HAZARD - DUE TO THE HIGH VOLTAGES ASSOCIATED WITH ITS OPERATION 

ONLY QUALIFIED SERVICE PERSONNEL SHOULD INSTALL OR TROUBLESHOOT THIS TRANSFER 

SWITCH! ALL APPLICABLE CODES AND STANDARDS MUST BE MET WHEN INSTALLING THIS 

DEVICE. SEE WIRING DIAGRAM INSIDE OF THE COVER AND ON THE BACK OF THIS PAGE.  

IMPROPER HANDLING OR INSTALLATION MAY CAUSE SERIOUS INJURY OR DEATH. 

 

WARNING:

 THE 5200 & 5300 SERIES AUTOMATIC TRANSFER SWITCHES ARE NOT IGNITION 

PROTECTED AND SHOULD NOT BE MOUNTED IN THE SAME COMPARTMENT AS BATTERIES OR 

FLAMMABLE MATERIALS SUCH AS GASOLINE. DO NOT MOUNT THE TRANSFER SWITCH IN THE 

GENERATOR OR LP GAS COMPARTMENT. A FIRE CAUSING PROPERTY DAMAGE SERIOUS INJURY 

OR DEATH COULD RESULT! 

 

THESE PRODUCTS ARE NOT DESIGNED FOR USE WITH 240 VOLT SINGLE LEG SUPPLIES. 

APPLICATION OF VOLTAGES IN EXCESS OF 130 VOLTS FROM HOT TO NEUTRAL MAY CAUSE 

PERMANENT DAMAGE TO THE UNIT. 

  

The 5200 & 5300 Automatic Transfer Switches can be installed as shown in figures 1 and 2 provided there is room to route the shore 
power, generator, and distribution connection wires. The 5200 & 5300 Automatic Transfer Switches including the Remote Display are 
not suitable for outdoor locations and should be mounted in a protected area. We recommend that the transfer switch be mounted as 
close to the shore power and generator power cords as practical to reduce voltage loss. 
  

REFER TO WIRING DIAGRAMS LOCATED INSIDE THE COVER FOR ALL 

CONNECTION INFORMATION AND TORQUE REQUIREMENTS. 

  

PROPER MOUNTING CONFIGURATIONS: 

 

               

 

 
 

 

OPTIONAL VOLTAGE SENSE CONNECTION: 

(Used for Auto Generator Start) 

 

For transfer switches supplied with the optional voltage sense PCB assembly, connect the ’16 VAC OUT’ connections to the ‘Shore 
Power Present’ inputs of your generator control center.  These connections do not have a polarity requirement.  This output will be 
16VAC whenever shore power is present. 

 

Figure 1 – Horizontal Wall Mount

Figure 2 – Floor Mount 

Summary of Contents for PD52 Series

Page 1: ...AVINGS LOSS OF USE OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT THIS INCLUDES DAMAGES TO PROPERTY AND TO THE EXTENT PERMITTED BY LAW DAMAGES FOR PERSONAL INJURY THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IV PROOF OF PURCHASE A warranty claim must be accom...

Page 2: ...RE NOT DESIGNED FOR USE WITH 240 VOLT SINGLE LEG SUPPLIES APPLICATION OF VOLTAGES IN EXCESS OF 130 VOLTS FROM HOT TO NEUTRAL MAY CAUSE PERMANENT DAMAGE TO THE UNIT The 5200 5300 Automatic Transfer Switches can be installed as shown in figures 1 and 2 provided there is room to route the shore power generator and distribution connection wires The 5200 5300 Automatic Transfer Switches including the R...

Page 3: ...he HOT1 side must be used for the control circuitry to work For models with surge protection both HOT1 and HOT2 must have power applied for proper operation HOW TO DISABLE GENERATOR TIME DELAY PD52DCSD REMOTE DISPLAY PD52 53 CONTROL BOARD To DISABLE the time out function of the control board INSTALL a 100 jumper of the connector at J1 PD52DCS CONTROL BOARD To DISABLE the time out function of the c...

Page 4: ...ING GUIDE PROBLEM POSSIBLE CAUSES ACTION No Output when Plugged into Shore Power Wiring error between shore power and the transfer switch Correct wiring Defective transfer switch Replace transfer switch Wiring error between generator and the transfer switch Correct wiring Generator malfunction Have generator serviced No Output when Generator is Running Wiring error between generator and the transf...

Reviews: