Progressive Dynamics PD2020 Owner'S Manual Download Page 7

-13-

Inteli-Power

Charger 1

Inteli-Power

Charger 2

1

1

2

2

3

3

GND

GND

Engine # 2

12 Volt Battery

+

-

House

12 Volt Battery

+

-

Bow Thruster

12 Volt Battery

-

+

Bow Thruster

12 Volt Battery

-

+

Engine # 1

12 Volt Battery

+

-

Engine # 1

12 Volt Battery

-

+

Engine # 2

12 Volt Battery

-

+

Output Voltage = 12 Volts

Output Voltage = 24 Volts

Series Connection:

Wiring the Intelipower chargers as shown below will provide a combination of 12

and 24 volt charging system.  This can eliminate the need to install expensive battery
equalizers and additional chargers for the 12 volt house and 24 volt bow thruster
batteries.

The Series system shown above will provide 24 volt charging for the bow thruster and
engine batteries while supplying 12 volt charging for the house battery.

-14-

Do not replace the converter unless the following checks have been performed:
1.

Loosen the screw on all the positive terminals and disconnect the positive wires. 
Read the converter output voltage using a DC voltmeter.  If the voltage is above 13
volts, the converter is working properly.

2.

If the converter output is zero volts, use an AC voltmeter to check for proper voltage
on the 120 VAC power source.  This voltage should be between 104 and 130 volts.

3.

Check the fuse(s) located next to the output terminal block inside the converter.  The
fuse(s) will only blow if the battery or DC output leads were connected in reverse,
even for a moment.  Replace the fuse(s) and repeat step 1.

SPECIFICATIONS

PD2020

Input: 105-130 VAC 50/60 Hz

350 Watts

Output: 13.6 VDC, 20 Amps

Dimensions: L= 10.2" W= 7.8" H=4.2"

Weight: 6lbs

PD2030

Input: 105-130 VAC 50/60 Hz

550 Watts

Output: 13.6 VDC, 30 Amps 

Dimensions: L= 10.2" W= 7.8"  H= 4.2"

Weight: 6.25lbs

PD2060

Input: 105-130 VAC 50/60 Hz

1000 Watts

Output: 13.6 VDC, 60 Amps

Dimensions: L= 10.2" W= 7.8"  H= 4.2"

 Weight: 6.5lbs

PD2040

Input: 105-130 VAC 50/60 Hz

650 Watts

Output: 13.6 VDC, 40 Amps

Dimensions: L= 10.2" W= 7.8"  H= 4.2"

 Weight: 6.25lbs

PD2050

Input: 105-130 VAC 50/60 Hz

900 Watts

Output: 13.6 VDC, 50 Amps

Dimensions: L= 10.2" W= 7.8"  H= 4.2"

 Weight: 6.5lbs

PD2080

Input: 105-130 VAC 50/60 Hz

1300 Watts

Output: 13.6 VDC, 80 Amps

Dimensions: L= 10.2" W= 7.8"  H= 4.2"

 Weight: 8.8lbs

©2002 Progressive Dynamics, Inc. All rights reserved.  Quiet Sensor is a registered
trademark of Progressive Dynamics, Inc. 
PATENT NUMBERS 5,600,550,  5,687,066, 5982,643 and 6,184,649.

Summary of Contents for PD2020

Page 1: ...al Charge Management System for recharging and maintaining marine batteries by providing 3 modes of operation Normal Boost Trickle Progressive Dynamics Inc 507 Industrial Rd Marshall MI 49068 269 781...

Page 2: ...your aid when you work near a lead acid battery 2 2 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 2 3 Wear complete eye protection and clothing protect...

Page 3: ...S E R I E S PD Input Outputs Volts Amps Cell Type Number of Cells Volts 105 135 VAC Hz 50 60 Watts 1000 3 13 6 VDC 60 Total Lead Acid 6 U S Patent No 5 600 550 5 687 066 Other Patents Pending 109734RA...

Page 4: ...e terminals for up to three battery banks One common negative terminal is provided for connection to all battery banks 5 9 INSTALLING EXTERNAL FUSE S not supplied An external fuse or circuit breaker n...

Page 5: ...er senses the battery voltage has dropped below a preset level the system automatically switches into the Boost Mode In this mode the charge voltage is increased to 14 4 volts for a period of approxim...

Page 6: ...tage 2 Internal Fuse s Blown Reverse Battery Hook Up Correct Hook up and replace Fuse s with same type and rating 3 Converter cycles on off Compartment gets too hot Check air flow to the converter Imp...

Page 7: ...output is zero volts use an AC voltmeter to check for proper voltage on the 120 VAC power source This voltage should be between 104 and 130 volts 3 Check the fuse s located next to the output termina...

Page 8: ...emoving and reinstalling the battery charger and F ANYLOSTPROFITS LOSTSAVINGS LOSSOFUSEOFENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITYTOUSE THEPRODUCT THIS INCLUDES DAMA...

Reviews: