Progressive Dynamics PD1600 Series Installation And Operation Manual Download Page 12

 

 12 

Figure 14 

Display Indicators

 

Display Interface 

Error 
Code 

Condition 

Description 

E-1 

Low battery volt-
age detected 

Input voltage has dropped beneath 10.5V for 
several seconds. The PD1600 Series inverter 
will automatically restart when the input 
voltage reaches 12.0V. 

E-2 

High battery volt-
age shutdown  

Input voltage has surpassed 15.5V. The 
PD1600 Series inverter will automatically 
restart when the input voltage falls below 
15.0V. 

E-3 

AC output over-
load shutdown 

Output power has surpassed the continuous 
power limit or the peak power limit. The 
PD1600 Series inverter will not automati-
cally restart. A manual restart is necessary  

E-4 

Over-temperature 
shutdown 

Internal temperature of the inverter has ex-
ceeded its safe operating limit. The PD1600 
Series inverter will automatically restart 
when internal temperatures return to safe 
operating conditions. 

ERROR CODES 

E-5 

Internal Error 

An internal error has been detected. The 
PD1600 Series inverter will not automati-
cally restart. A manual restart is necessary  

E-6 

Short Circuit 

A short circuit has been detected on the AC 
output of the inverter. The inverter will not 
restart. A manual restart is necessary. 

Display Features 



Power Button: Press to turn on; hold to turn off 



Select Button: Cycles between display states:  

 

Input Voltage, Output Voltage, Output  

 

Power, Sleep, Error Code (if applicable) 



Power Indicator: Lights up green when the inverter is on 



Fault Indicator: Flashes red when an error has occurred 



Shore Indicator: Lights up yellow when AC input is detected 



Low Bat Warning Indicator: Lights up red when the battery 
is nearing the end of its charge 



Sleep: Lights automatically dim after 30 seconds 



Remote port for externally mounted display 

Figure 13 

Error Code Descriptions

 

Figure 12 

PD1601

 

Remote Display

 

Rear Remote Connection 

NOTE: 

For troubleshooting error codes, consult page 14 

NOTE: 

Remote display operates exactly the same as the dis-

play mounted to the inverter 

Power Indicator 

Shore Power Indicator 

Low Bat Warning Indicator 

Fault Indicator 

Figure 11 

Display Panel

 

Select Button  Display  Power Button 

PDI Comm Port  RV-C Comm Port 

Summary of Contents for PD1600 Series

Page 1: ...onal and commercial vehicle industry in mind the PD1600 Series Inverter was designed to be compact and light weight to fit the strict size and weight constraints often found within vehicles The improved thermal design reduces the ventilation space required which contributes to a even smaller space requirement for your inverter Progressive Dynamics Inc has a complete line of power products for your...

Page 2: ...reinstalling the power inverter E ANY LOST PROFITS LOST SAVINGS LOSS OF USE OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT THIS INCLUDES DAMAGES TO PROPERTY AND TO THE EXTENT PERMITTED BY LAW DAM AGES FOR PERSONAL INJURY THIS WARRANTY IN IN LIEU OF ALL OTHER WARRANTIES INCLUDING WARRANTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSES...

Page 3: ...618 1800W Inverter PD1620 2000W Inverter PD1601 25 25 Remote Display Included with unit PD1601 50 50 Remote Display Sold Separately All products include a quick reference guide with specifications and installation instructions Figure 1 PD1600 Series Inverter Components Inverter units available with optional input power cord in stalled ...

Page 4: ...al AC power 5 AC Output Knockout Knockout to be removed when connecting to hardwired AC Output 6 AC DC Access Panel Remove access panel to wire install AC and DC wiring 7 Equipment Ground Lug Connect case to earth ground to ensure proper safe operation 8 On Board Display Display monitors all relevant parameters of the PD1600 Series Inverter Figure 2 PD1600 Series Inverter AC DC End View Figure 3 P...

Page 5: ...maging the batteries The inverter may also be used with a 12V lithium ion battery pack LiFePO4 with a properly configured BMS See Specifications on page 16 for voltage limits Fully Functional Remote Display Optional When purchasing your inverter an optional addition is the remote display The PD1600 Series Inverter has an optional remote display that is fully functional at up to 50 feet away This i...

Page 6: ...NSFER SWITCH PD55 SERIES AC DISTRIBUTION PANEL GROUND GROUND TO DC LOADS DC GROUND GROUND TO AC LOADS HOT SHORE GENERATOR ONLY 30A 20A TO AC LOADS HOT SHORE GENERATOR INVERTER 15A 20A GENERATOR SHORE CONNECTION PD1600 SERIES INVERTER AC IN AC OUT DC DC SHORE NEU PANEL HOT PANEL NEU GEN NEU GEN HOT NOTE REFER TO WIRING DIAGRAM INCLUDED WITH PD51 SERIES TRANSFER SWITCH SHORE HOT ...

Page 7: ...ttery Bank PD60 SERIES DC DISTRIBUTION PANEL MAIN SUB PD55B006 AC DISTRIBUTION PANEL GROUND GROUND TO DC LOADS DC GROUND GROUND TO AC LOADS HOT SHORE GENERATOR ONLY TO AC LOADS HOT SHORE GENERATOR INVERTER 20A 20A 50A 15A GENERATOR PD9200 SERIES CONVERTER SHORE CONNECTION PD1600 SERIES INVERTER AC IN AC OUT DC DC ...

Page 8: ... compartment directly above the inverter compartment to avoid the potential for battery acid drips In order to reduce cable losses and maximize system performance the DC input wires should be kept as short as possible See Page 10 for recommended DC input wire sizes and lengths Orientated Properly It is recommended that the PD1600 series inverter is mounted horizontally with the display facing up T...

Page 9: ...t the wiring compartment is facing down see Figure 5 This will ensure that the display will be oriented correctly It is best to ensure that PD1600 series inverter is placed in an area that keep dust debris from entering the fan area Debris may cause unexpected performance issues in your inverter 5 Pilot drill the mounting holes in the marked locations 6 Secure the PD1600 Series Inverter firmly to ...

Page 10: ...NING FIRE SHOCK AND ENERGY HAZARD Make sure wiring is disconnected from all electrical sources before handling All wiring must be done in accordance with local and na tional electrical wiring codes Failure to follow these instructions may result in serious injury or death Electrical Connection Instructions 1 Ensure all power sources are disconnected from the inverter 2 Remove the Wiring Cover 3 Re...

Page 11: ... Install wiring into terminal blocks Metal Clamp Style Halex 20570 or equivalent 3 8 trade size clamp combination connector Material Zinc plated metal Installation Instructions 1 Insert strain relief into 3 8 trade size opening 2 Slide wire through central opening 3 Push stripped wires into terminals blocks 4 Tighten the strain relief using screws on the side The type of 3 8 trade size strain reli...

Page 12: ...nverter will not automati cally restart A manual restart is necessary E 6 Short Circuit A short circuit has been detected on the AC output of the inverter The inverter will not restart A manual restart is necessary Display Features Power Button Press to turn on hold to turn off Select Button Cycles between display states Input Voltage Output Voltage Output Power Sleep Error Code if applicable Powe...

Page 13: ...Shore Fault and Low Battery Indicators in sleep mode will be noticeably dimmer than in any other state The PD1600 Series Inverter display automatically enters sleep mode when neither of the control buttons have been pressed for 30 seconds The inverter will automatically exit sleep mode when any error occurs or shore power is detected To manually exit sleep mode press either button Pressing the pow...

Page 14: ...he input voltage has exceeded 15 5VDC Inverter will automatically restart when DC Input voltage is decreased to 15 0VDC Turn off the inverter by holding down the power button Locate DC source and verify it is properly connected for 12VDC operation E 3 is displayed An over load condition has been detected This can be excessive power or a peak power that exceed 2X rated power A manual restart is req...

Page 15: ... the provided 25 cable Inverter turned off for seemingly no reason Something has interrupted the communication between the display and the inverter Ensure that the equipment ground wire is properly secured to the equipment ground lug For Further Assistance Contact PDI Service Department service progressivedyn com WARNING FIRE SHOCK OR ENERGY HAZARD DO NOT disassemble the inverter It does not conta...

Page 16: ...iodic Send Description Product ID n a When requested the inverter responds with the make and model Progressive Dynamics PD1600 Series vX XX DM RV 4 seconds Provides information on Service Points in the event of a fault Inverter AC Output Page 1 0 1 seconds Provides information on AC output frequency and voltage Inverter AC Output Page 2 0 1 seconds Provides information on AC bypass ampacity Invert...