• Do not let mains cables touch or come
near the appliance door or the niche
below the appliance, especially when it
operates or the door is hot.
• The shock protection of live and
insulated parts must be fastened in
such a way that it cannot be removed
without tools.
• Connect the mains plug to the mains
socket only at the end of the
installation. Make sure that there is
access to the mains plug after the
installation.
• If the mains socket is loose, do not
connect the mains plug.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• Use only correct isolation devices: line
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
• The electrical installation must have an
isolation device which lets you
disconnect the appliance from the
mains at all poles. The isolation device
must have a contact opening width of
minimum 3 mm.
• This appliance is supplied with a main
plug and a main cable.
• The hob connection socket is at the top
of the oven cabinet. The hob has
connection leads for the cooking zones
and the ground cable. The leads have
plug-in connectors. Plug the connectors
into the correct oven socket to connect
the hob to the oven. The design of the
plugs and sockets prevents incorrect
connections.
If the mains voltage is different, rearrange
the jumpers on the terminal board (refer to
the connection diagram below). Connect
the ground cable to the terminal. After you
connect the supply cable to the terminal
board, attach it with a junction clamp.
Connecting to terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for op‐
eration on a 400 V three-phase with a neu‐
tral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1
N
L2
L1
N
N
L2
L3
L1 L2 L3
PE
PE
PE
PE
Cable types applicable for installation or
replacement for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate.
Progress 5