Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
Building In
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
150 mm
30 mm
10 mm
86 mm
86 mm
A
3 mm
A
B
A) supplied seal
B) supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
b
a
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the
indication and the kitchen unit must be
equipped with vents to let a continuous
supply of air. The electrical connection of
the hob and the oven must be installed
separately for safety reasons and to let easy
remove oven from the unit.
50 cm
2
360 cm
2
180 cm2
120 cm
2
progress
17
Summary of Contents for PAG7530E
Page 46: ...46 progress...
Page 47: ...progress 47...
Page 48: ...www progress hausgeraete de 397182201 B 212012...