background image

Limited Lifetime Warranty

Date Purchased

Store Purchased

UL Model No.

Serial No.

Vendor No.

UPC

111017

P2560

Progress Lighting fan motors are warranted to the original purchaser to be free of electrical and/or mechanical 

defects for so long as the original purchaser owns the fan. Pull chain switches, reverse switches, capacitors and 

metal finishes are warranted to be free from defects in materials or workmanship for a period of 1 year from 

the date of purchase. Warping of wooden or plastic blades is not covered by this warranty nor is corrosion and/

or deterioration of any finishes for fans installed within ten miles of any sea coast. Extended warranties for 

ENERGY STAR

®

 qualified products may apply.

Progress Lighting ceiling fans with built-in LED light sources, when properly installed and under normal 

conditions of use, are warranted to be free from defects in material and workmanship which cause the light 

sources to fail to operate in accordance with the specifications for (i) five (5) years from the date of purchase 

on the LED Light modules and electrical components for fans used in single family residences, and (ii) three 

(3) years from the date of purchase on the LED Light modules and electrical components for fans used in 

multi-family or commercial applications. LED bulbs supplied by Progress Lighting carry no warranty other 

than manufacturer’s warranty. Non-LED bulbs carry no warranty.
With proof of purchase, the original purchaser may return the defective fan to the place of purchase during the 

first 30 days for replacement. After 30 days, the original purchaser MUST contact Progress Lighting at (864) 

678-1000 for repair or replacement which shall be determined in Progress Lighting’s sole discretion and shall 

be purchaser’s sole and exclusive remedy.
Labor  and  Shipping  Excluded.  This  warranty  does  not  cover  any  costs  or  fees  associated  with  the  labor 

(including, but not limited to, electrician’s fees) required to install, remove, or replace a fan or any fan parts.
This warranty shall not apply to any loss or damage resulting from (i) normal wear and tear or alteration, 

misuse, abuse or neglect, or (ii) improper installation, operation, repair or maintenance by original purchaser 

or a third party, including without limitation improper voltage supply or power surge, use of improper parts or 

accessories, unauthorized repair (made or attempted) or failure to provide maintenance to the fan.
THE FOREGOING WARRANTIES STATE PROGRESS LIGHTING’S ENTIRE WARRANTY OBLIGATION 

AND ORIGINAL PURCHASER’S SOLE AND EXCLUSIVE REMEDY RELATED TO SUCH PRODUCTS. 

PROGRESS LIGHTING IS NOT RESPONSIBLE FOR DAMAGES (INCLUDING INDIRECT, SPECIAL, 

INCIDENTIAL OR CONSEQUENTIAL), DUE TO PRODUCT FAILURE, WHETHER ARISING OUT OF 

BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. THIS WARRANTY IS GIVEN 

IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED, INCLUDING THOSE 

OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitations 

of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This 

warranty gives you specific rights and you may have other rights which vary from state to state.

785247 221752
785247 221769

785247 250080

785247 250073

Summary of Contents for 785247221752

Page 1: ...P2560 93089915_BB...

Page 2: ...After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discretion and shall be purchaser s...

Page 3: ...lling Your Fan Setting the Codes on Remote Control and Receiver Making the Electrical Connections Finishing the Fan Installation Operating Your Fan Care of Your Fan Troubleshooting Specifications Tabl...

Page 4: ...ections spliced conductors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one...

Page 5: ...ssembly 6 Switch Cup Adaptor 7 Switch Cup 8 Blade 5 9 Transmitter and Receiver 1 Mounting Bracket inside canopy 2 8 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy R...

Page 6: ...l box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 20 If the canopy touches downrod remove the decorat...

Page 7: ...s are on top Route the wires through the canopy and then through the ball downrod assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not rem...

Page 8: ...he two screws provided with the outlet box If necessary use leveling washers not included between the mounting bracket and the outlet box Note that the flat side of the mounting bracket is toward the...

Page 9: ...rtment in the back side of the transmitter B Slide code switches to your choice of up or down position factory setting is up C Replace the battery cover on the battery compartment of the transmitter 2...

Page 10: ...Remote control model UC7067RYE 7 Making the Electrical Connections IF OTHER FAN OR SUPPLY WIRES ARE DIFFERENT PLEASE HAVE THIS UNIT INSTALLED BY A LICENSED ELECTRICIAN Follow the steps below to conne...

Page 11: ...D CEILING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two...

Page 12: ...g in the switch cup with the molded adaptor plug of the fan motor assembly Figure 15 4 Attach the switch cup to the fan by aligning the three screws holes on switch cup with the screw holes on the swi...

Page 13: ...ling effect as shown in Figure 18 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling...

Page 14: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Page 15: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipme...

Page 16: ......

Page 17: ...P2560 93089915_B Manual de instalaci n del ventilador de techo B...

Page 18: ...ra Pasados 30 d as el comprador original TIENE que contactar a Progress Lighting llamando al 864 678 1000 para reparaci n o reposici n seg n determine Progress Lighting a su entera discreci n y este s...

Page 19: ...or C mo configurar los c digos del control remoto y el receptor C mo hacer las conexiones el ctricas C mo finalizar la instalaci n del ventilador C mo usar el ventilador Cuidado del ventilador Soluci...

Page 20: ...s hacia arriba y empujarlos con cuidado hacia dentro de la caja de distribuci n Los cables deben estar separados con el cable y el conductor a tierra del equipo hacia uno de los lados de la caja el ct...

Page 21: ...nterruptor 8 Aspas 5 9 Transmisor y receptor 1 Soporte de montaje dentro de la cubierta 2 Conjunto de tubo bajante bola de 8 20 3 cm pasadores de soporte y de cierre prefijados 3 Cubierta con aro de c...

Page 22: ...stalar el ventilador en un techo inclinado El ngulo m ximo permitido es 20 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubierta 180 antes de fijarla a la placa...

Page 23: ...Remove Loosen but Do Not Remove Figura 5 Figura 6 5 Afloja sin quitarlos los tornillos de fijaci n en el collar n de la parte superior de la carcasa de motor 6 Alinea los orificios en la parte inferi...

Page 24: ...o Aseg rate de que la pesta a en el soporte de montaje est bien asentada dentro de la ranura de la bola de soporte Figura 9 Figura 8 Electrical Box Figura 9 Caja el ctrica aprobada por UL Soporte de m...

Page 25: ...r del transmisor B Desliza los interruptores de c digo como desees hacia arriba o hacia abajo la configuraci n de f brica es hacia arriba C Coloca de nuevo la cubierta sobre el compartimento de las ba...

Page 26: ...ptor usando una tuerca de cable Figura 11 5 Conecta el cable NEGRO del receptor al cable NEGRO de suministro de energ a positivo usando una tuerca de cable Figura 11 6 Conecta el cable BLANCO del rece...

Page 27: ...s Touching Ceiling MONTAJE EST NDAR EN TECHO 1 Alinea las ranuras de cierre de la cubierta de techo con los dos tornillos de la placa de montaje Empuja hacia arriba para enganchar las ranuras y gira d...

Page 28: ...do del conjunto motor ventilador Figura 15 4 Fija la caja del interruptor alineando los tres orificios de tornillos en ella con los orificios correspondientes en el adaptador Inserta los tres tornillo...

Page 29: ...la Figura 18 Esto permite fijar tu aire acondicionado en configuraci n m s alta sin afectar tu comodidad Clima fr o Reversa Un flujo de aire hacia arriba desplaza el aire c lido lejos del techo como m...

Page 30: ...lectricidad est apagada 3 Verifica las bater as en el transmisor Se enciende la luz LED roja Est s lo suficientemente cerca del ventilador El rango normal es de 10 20 pies 3 a 6 metros Coinciden las c...

Page 31: ...a a comunicaciones radiales Sin embargo no hay garant a de que no ocurrir interferencia en una instalaci n particular Si este equipo causa interferencia perjudicial a la recepci n de radio o televisi...

Page 32: ......

Reviews: