background image

 
 
 
 
 
 
 
 
 

Preva Plus Upgrade Instructions 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

               FORM #00-02-0594 

ECN: P1713 

Rev. C 

Summary of Contents for Preva Plus

Page 1: ...Preva Plus Upgrade Instructions FORM 00 02 0594 ECN P1713 Rev C ...

Page 2: ...equired for this upgrade may include one or more of the following Part Numbers 600 401 Upgrade Kit with 1 Sensor 600 402 Upgrade Kit with 2 Sensor 600 403 Upgrade Kit with 1 and 2 Sensor 600 404 Upgrade Kit without Sensor Options 600 100 USB Ethernet Extender 30 A2153 USB A B Switch Tools Required Philips Screwdriver 1 Philips Screwdriver 2 3mm Hex Wrench Diagonal Cutter Copyright 2008 Progeny Inc...

Page 3: ...cate the cable tie that holds the end of the USB cable to the arm Refer to Figure 2 Figure 2 3 Carefully cut the cable tie with a diagonal cutter Take extreme care not to cut the USB cable jacket 4 Plug the USB cable into J1 of the Sensor Interface PCB Arm Mount Kit Refer to Figure 3 FORM 00 02 0594 ECN P1713 REV C ...

Page 4: ...er over the end of the Articulating Arm 6 Secure the Sensor Interface PCB Arm Mount Kit to the Articulating Arm using the M3 x 16mm socket head cap screw Use a 3mm hex wrench to tighten Refer to Figure 4 Figure 4 7 Attach the sensor holder to the articulating arm as shown in Figure 5 FORM 00 02 0594 ECN P1713 REV C ...

Page 5: ...e 5 8 Plug the sensor connector into the Sensor Interface at the bottom of the Arm mount Figure 6 Figure 6 9 Place the sensor into the sensor holder Refer to Figure 7 Figure 7 FORM 00 02 0594 ECN P1713 REV C ...

Page 6: ... cable provided to J2 of the Unpowered USB Hub Refer to 15 in the control cover using one of the provided access areas See fig 8a 10 Remove the cover from the Preva Plus Control Unit Attach the Unpowered USB Hub to the bracket adjacen Figure 8 Locate the free end of the USB cable from with a cable tie carefully cut the cable tie Plug the USB cable Refer to Figure 8 Connect th Figure 8 Cut and clea...

Page 7: ...ered hub at the computer to prevent overloading and any electrical power issues at the computer Plug the 4 Port USB Hub Power Supply into a wall outlet Connect the power s USB Hub OPTION 2 USB Ethernet Extender part number 600 100 This extender provides for a longer cable run than permitted by US pter is used on both the computer end and the sensor end with an ethernet between that can run up to 2...

Page 8: ...Switch ma a ub from the bracket inside the Control Unit Plug the two USB cables for each of the two PCs into J1 and J3 on the Dual Host Switch Assembly Refer to Figure 10 e Host with Enclosure Refer to Figure 10 Figure 10 f Use the 50 foot CAT V Cable to link to the USB Ethernet Extender Device cover and replace the cover OPTION 3 Dual Host Switch part number 30 08135 In the case whe y be used Rem...

Page 9: ...the two USB cables through the notch in the bottom of the Control Unit cover and replace the cover Refer to Figure 10 Figure 12 Plug one USB cable into a USB Port on each of the PCs in use FORM 00 02 0594 ECN P1713 REV C ...

Page 10: ...d route the USB cable and the control panel computer cable through the hole in the cradle bas as shown in figure 13 b Route the control panel computer cable through the cradle and the USB cable in the slot at the bottom of the cradle as shown in figure 14 FORM 00 02 0594 ECN P1713 REV C ...

Page 11: ...Figure 14 c Attach the control panel computer cable to the control panel as shown in figure 14 d Place the control panel on to the cradle as shown in figure 15 Figure 15 FORM 00 02 0594 ECN P1713 REV C ...

Page 12: ... hub acts as an unpowered USB hub in this installation Figure 16 f Attach the USB cable that came with the system into the hub and the other end into a USB port on the computer which contains the imaging software necessary to operate the sensor and acquire radiographs g Installation is now complete and the computer may be used to invoke the imaging software FORM 00 02 0594 ECN P1713 REV C ...