LOCATING THE HEATER
Install heater out of traffic areas, maintaining clearances stated in figure 3. The direction of air flow
should not be restricted by columns or machinery and the air flow should wipe exposed walls
rather than blowing directly on them. When more than one heater is used in an area, the heaters
should be installed in a way that the air discharge of each heater supports the air flow of the
others, to provide best circulation of warm air as indicated in figure 4.
14in.
MINIMUM
DISTANCE
TO WALL
MINIMUM
DISTANCE
TO WALL
4
1
2
in.
10
3
5
in.
4
1
2
in.
36 in.
12
1
2
in.
13in.
7
3
8
in.
1
3
4
in.
MINIMUM
DISTANCE
FROM
DISCHARGE
TO ANY
OBJECT
Note: Min. clearance to ceiling
when not using mounting brackets
1
2
in. .,
3
4
in.
MINIMUM
DISTANCE
TO FLOOR
At least 8
ft.
is 1
5
8
in.
FRONT VIEW
MAXIMUM MOUNTING HEIGHT:
Vertical air delivery unit = 11 ft.
Horizontal air delivery unit =8 ft .
SIDE VIEW
Figure 4
Figure 3