Byte av batteri 

Dra den fjäderbelastade knappen (kl.12 på knappsatsen) mot dig och vrid försiktigt knappsatsens ring motsols tills det tar stopp. Dra ringen försiktigt mot dig och 
batteriutrymmet blir synligt. Skifta batteri. Duracell 9V alkaliska rekommenderas. Säkerställ att inga kablar ligger i kläm, tryck sedan tillbaka ringen mot 
monteringsplattan och vrid ringen medsols till sitt ursprungsläge. Knappen skall nu snäppa tillbaka. Kontrollera låsets funktion minst 3 gånger innan skåpsdörren 
stängs. 
 

Övrig programmering 

Se ”Programmeringsguide Sargent & Greenleaaf Titan Pivot Bolt / Titan Direct Drive & 6124/6125” 

 
  

 

        

 

Content 

 

 

 

Page: 

           

1.) 

Introduction 

 

 

 

 

2) 

Transporting 

 

 

 

3.) 

Instruction for anchoring to floor 

 

 

4.) 

Lock instruction for changeable keylock  

 

5.) 

Cover inside of the door 

 

 

6.) 

Maintenance and control 

 

 

7.) 

Warranty 

 

 

 

8.) 

Quick guide digital lock 

 

 

 

 

 

 

 

 

 

1. 

Introduction 

 
The deposit safe is a concrete filled safe. As standard the safe is fitted with changeable key lock (two keys). As accessories there are detachable keys available. 
Different set of keys for each lock. The safe is prepared to take digital locks with dead bolt (threaded holes). Locks with swing bolt cannot be used. 
 

2. 

Transporting 

 
The deposit safe is transported fixed on a pallet. The safe is fixed to the pallets.  Corners etc. are protected and the safe is wrapped in transparent plastic.  
 

3. 

Instruction for anchoring to floor 

 
For your security the deposit safe should always be fixed to the floor. Always ensure that the floor can take the weight of the safe and that nothing in the floor can 
get damaged during fixing of the safe. We recommend that all cabinets bolted. Drill holes diam.16 mm and if possible 100 mm deep. 

 
Use the following: 
A) Hard concrete: 16 mm anchor bolts 
B) Porous concrete Ø 16 mm plastic plug and 14 mm wood screws 
C) Wooden joists: Ø 16 mm wood screws 

 
4. 

Lock instruction– changeable key lock 

 

 
Read instruction before starting the changing procedure. Key changing function should always be made with the safe door open. 
The key must always be taken away from the lock after use in order to avoid unauthorized use. Always keep the key in a safe place. The safe is delivered with the 
lock in 0-position. In the event of key loss, lock must be re-set with new key as soon as possible in order to maintain maximum security. 
Change procedure: 

 

Open the door fully, with the door open throw the bolt work to the fully closed position. 

 

Depress the change bottom on the back of the lock body. 

 

While holding down the button turn key until bolt is fully retracted, i.e. lock open. 

 

When bolt is fully retracted, remove key and release pressure on the button. 

 

Insert new key and turn key until bolt is fully extended i.e. lock closed. 

 

Turn key several times to the locked unlocked position to ensure that change has been effected correctly. Shut the door, secure and remove key. 
 

 

 

 

 

 

5.  

Cover inside of the door 

 
Inside of the cover plate inside the door you find the locking mechanism and the lock. Note that access inside the cover plate is only allowed for authorized person. 
Access by non-authorized person may result in that warranty is no longer valid. 

 
6.  

Maintenance and Controls 

 
Annual maintenance should be carried out on the deposit safe to ensure trouble-free usage: 

 

Checking function of the lock 

 

Checking function and smooth movement of the locking bolt. 

 

If necessary greasing of the hinges 

 

If necessary greasing of the moving parts in the locking mechanism but not the lock itself. 

 

Checking the steel wire for the re-locker. 

 

NOTE: Never grease any lock! Allow only authorized person to work with the lock and the locking mechanism. 
 
 