Save and recall settings
It is possible to save up to three combined energy level, modeling light, ready signaling,
auxiliary functions, sync/remote and radio settings in the memory of generator.
Save to memory
1. Press and hold down the Recall/Save Button [11] to enter Memory Mode. The Ready
Lamp [18] will turn off and a double beep signal will confirm that Memory Mode is
entered.
2. While still holding down the Recall/Save Button [11], press and hold down the Head/
Model Button [12] corresponding to the memory you want to use; B, C or D.
3. While still holding down the Head/Model Button [12], release the Recall/Save Button
[11].
4. Release the Head/Model Button [12]. The Ready Lamp [18] will turn on again.
Recall from memory
1. Press and hold down the Recall/Save Button [11] to enter Memory Mode. The Ready
Lamp [18] will turn off and a double beep signal will confirm that Memory Mode is
entered.
2. While still holding down the Recall/Save Button [11], shortly press the Head/Model
Button [12] corresponding to the memory you want to recall from; B, C or D. The stored
energy level settings will be shown in the Energy Displays [10].
3. While still holding down the Recall/Save Button [11], it is possible to select another
memory to recall settings from, by shortly pressing the corresponding Head/Model
Button [12].
4. When the desired memory settings are recalled, release the Recall/Save Button [11].
The Ready Lamp [18] will turn on again and a beep signal will confirm that the settings
stored in the memory now will apply.
Turn off generator
The current energy level, modeling light, ready signaling and sync/remote settings are
automatically saved and will be available at start up.
1. Press the On/Standby Button [3] to turn off the generator.
2. The Power Indicator [2] will still be green, indicating that the generator is receiving
power but is in standby mode.
3. Remove the power cable.