Power supply

The D4 Air generator can be connected to 100-240VAC, 50-60Hz. The generator 
automatically senses and adapts to the voltage and frequency supplied.

WARNING:

Never use ordinary household extension cables to elongate the power cable, since they may overheat. Always 
unwind all cable if an extension cable is used.

Lamp head configuration

The D4 Air generator is designed to – by configuration – be compatible with either the 
Acute/D4 series or the Pro series of heads. The default configuration is compatibility with 
the Pro series of heads. The configuration is easily changed; see instructions on page 17.

When the D4 Air is configured for the Pro series of heads, there is no need to change the 
modeling lamp when using Pro heads. The modeling light is powered correctly by the 
generator – worldwide.

When the D4 Air is configured for the Acute/D4 series of heads, it is important to use 
modeling lamps that correspond to the local mains voltage: 100V modeling lamps in 
100V markets, 120V modeling lamps in 110-120V markets and 240V modeling lamps in 
200-240V markets. 

PLEASE CHECK THE CONFIGURATION OF THE GENERATOR, THE MODELING LAMPS AND 
THE MAINS VOLTAGE BEFORE CONNECTING A FLASH HEAD!

Energy distribution

The D4 Air generator offers a flexible, fully asymmetric energy distribution to all four lamp 
sockets. Non-used sockets are automatically deactivated.

When only one lamp head is used, it should be connected to Lamp Head Socket A or B [9]. 
These sockets can be used to release the total energy (100%) of the generator to one lamp 
head. With one head connected to socket C, 50% of the total energy can be released and 
with one head connected to socket D, 25% can be released.

When two or more lamp heads are connected, the maximal energy level in total for all 
heads is of course 100%. It is not possible to select a higher energy level setting than the 
maximal; when the upper limit is reached, the energy level setting shown in the Energy 
Display [10] will stop at the maximal value even if you try to increase the energy level.

NOTE: 

Since the D4 Air works with separate capacitor banks for best color and f-stop stability, about 1/10 f-stop of the total 
energy may not be available at some settings when using two or more lamp heads.

Summary of Contents for D4 1200 Air

Page 1: ...D41200Air D42400Air D44800Air User s Guide...

Page 2: ...D4 1200 Air D4 2400 Air D4 4800 Air 2 www profoto com...

Page 3: ...ividual product comply with specified performance quality andsafety Forthisreasonourflashequipmentiswidelyusedin rentalstudiosandrentalhousesworldwide fromParis London Milan NewYork TokyotoCapeTown Pr...

Page 4: ...le time after being turned off Do not touch modeling lamp or flash tube when mounting umbrella metal shaftinitsreflectorhole Disconnectlampheadcablebetweengeneratorandlampheadwhenchanging modeling lam...

Page 5: ...ync and control 13 Auxiliary functions 13 Test function 15 Memory function 15 Additional information 16 Color Temperature 16 f stop stability 16 Flash duration 16 Petrol electric generators 16 Operati...

Page 6: ...om Miscellaneous 23 Measurements 23 Compatible heads 24 Old Profoto heads 24 Warranty 24 Regulatory information 25 World wide Usage of Radio Spectrum 25 EU Declaration of Conformity 25 Unites States a...

Page 7: ...irectlyandeveryadjustmentisdisplayedimmediately Itis possibletoactivateanddeactivateeachheadseparatelybythepushofabutton TheintegratedAirsystemoffersareliableradiosyncandcomfortableradioremotecontrol...

Page 8: ...ally or group them to control multiple generators at one time You can save customerlightingsetupsforuseatalatertime TheD4AirgeneratorcanbeconnectedtothePC MaceitherwithaUSBcableorwirelessly viatheProf...

Page 9: ...veButton 12 Head ModelButtons A D 13 EnergyControls A D 14 MasterButton 15 USBPort 16 ReadyModeIndicators 17 ReadyModeButton 18 ReadyLampandTestButton 19 ModelingLightButton 20 ModelingLightIndicators...

Page 10: ...age 100V modeling lamps in 100V markets 120V modeling lamps in 110 120V markets and 240V modeling lamps in 200 240Vmarkets PLEASE CHECKTHE CONFIGURATION OFTHE GENERATOR THE MODELING LAMPSAND THEMAINSV...

Page 11: ...flash to dischargethegeneratorwhentheenergylevelislowered Modelinglight TheHead ModelButtonsA D 12 areusedtoturnon offthecorrespondingmodelinglight TheModelingLightButton 19 isusedtoturnon offallthemo...

Page 12: ...dicate that the charging of the generator is completed BUZZ An audible signal with several beeps will indicate that the generator is being charged BEEP DIM The modeling light will be turned off while...

Page 13: ...hronizationandcontrol Forsync controlviaradio theProfotoAirreceiverinthegeneratormustbeactivatedanda radiochannelmustbeselected SeeRemotesync controlsetupinstructionsonpage20 The Profoto Air system op...

Page 14: ...rements pressdownthecontrolwhileturning Delay Turn Energy Control C 13 to select the delay time 0 1 60 s before the first flash Forchangesinlargerincrements pressdownthecontrolwhileturning Ifoneorseve...

Page 15: ...tions The D4 Air generator is equipped with an effective cooling and safety system The integrated fan will automatically start running when the generator is operating at higher energylevelsorwhenthege...

Page 16: ...tialwhenD4Airgeneratorsareused in combination with Multi Shot backs or for 3D pictures The power stability of the D4Air generatorsisinfactbetterthantherepeataccuracyofmostflashmeters Flashduration The...

Page 17: ...wingthreebuttons theWs f stopButton 11 andtheHead ModelButtonBandC 12 4 Whilestillpressingthethreebuttons connectthepowercabletotheMainsSocket 1 andtoACmainssupply 5 While still pressing the three but...

Page 18: ...P BUZZ BEEP DIM BUZZ DIM DIMorOFF 4 UsetheRechargingSpeedButton 18 toselectNormal unlitbutton orFast litbutton Rechargingspeed Auxiliaryfunctionssettings 1 Press the Set Button 7 twice The auxiliary f...

Page 19: ...or sync cord never via the computeranditssoftware Remotesync controlsetup 1 PresstheSetButton 7 oncetoenterauxiliarymode Thegroupsettingforeachhead willbedisplayedintheEnergyDisplays 10 2 TurntheEner...

Page 20: ...e Ready Lamp 18 will turn off and a double beep signal will confirm that Memory Mode is entered 2 While still holding down the Recall Save Button 11 shortly press the Head Model Button 12 correspondin...

Page 21: ...tructions onpage18 Thefuseofthelamp headand orthelamp bulbblows Thegeneratoris notconfiguredtobe compatiblewiththe connectedhead Configurethegenerator accordingtotheinstructions onpage17 Oneorseveralm...

Page 22: ...00Ws SocketC 9 600Ws SocketC 18 1200Ws SocketC 36 2400Ws SocketD 9 300Ws SocketD 18 600Ws SocketD 36 1200Ws AsymmetryRange max7 8f stops Recyclingtime 120V 60Hz 0 07 1 2s 0 09 2 2s 0 12 4 4s Recycling...

Page 23: ...ons Sequence Interval Delay Miscellaneous DigitalDisplay Yes f stops Ws Auxfunctionsandradiosettings FanCooled Yes temperatureregulated AutomaticMulti Voltage Yes 100 120V 200 240V 50 60Hz ReadySignal...

Page 24: ...7 heads However Profoto does not recommenduseofoldAcutePABandAcuteAlfaheads ABorABS NOTE Whenequippedwitha220 240V 50Hzmodelinglight PF PB Pro 6andPro 7headscanbeusedat220 240V 50Hz However Profotodo...

Page 25: ...e Radio and Telecommunications Terminal Equipment Act and Directive1999 5 EC R TTEDirective Manufacturer ProfotoAB Address Box2023 12821SKARPN CK Sweden Product 2 4GHzSRDcommunicationmodule Type Profo...

Page 26: ...SS 210 d Industrie Canada L utilisation de ce dispositifestautoris eseulementauxconditionssuivantes 1 ilnedoitpasproduiredebrouillageet 2 l utilisateur du dispositif doit tre pr t accepter tout brouil...

Page 27: ...rationinJapan Classificationofspecifiedradioequipment Article2 Clause1 Item19 2 4GHzWideBandLowPowerDataCommunication 38 24 1 Thisistocertifythattheabove mentionedcertificationbytypehasbeengrantedin a...

Page 28: ...ProfotoAB P O Box1264 SE 17225Stockholm SWEDEN Phone 4684475300 info profoto com www profoto com V3 Printed in Sweden Technical data and product information are subject to change without notice...

Reviews: