EN
FAUILURES
FAILURE
CAUSE
SOLUTION
Information on display
not visible
- Batteries empty
- Batteries inserted incorrectly
Replace the batteries
Insert the batteries correctly in the
product
Display shows F1
The valve is not responding properly
Re-install the product on the radiator
Display shows F2
The valve is too far from the radiator
Bolt on the fixing ring and ensure that
there is less distance between the
radiator and the thermostat head.
Display shows F3
The valve is too close to the radiator
Loosen the ring and ensure that there is
more distance between the radiator and
the thermostat head.
Display shows FULL
The memory is full
Disconnect one external device of
the thermostat head or disconnect all
external devices of the hermostat head
WARRANTY
The guarantee period for this product amounts to two years and commences on the date of purchase. During
this guarantee period Eltra nv will repair any defects attributable to material or production faults. Eltra nv may
choose to either repair or replace a defective appliance. Eltra nv is not obliged to repair or replace appliances
if they have become defective as a result of damage, inappropriate use, or modifications or adaptations
made after the purchase date. Take any defective appliance together with the original receipt back to the
shop where the appliance was sold. Always add a note with a description of the problem. Eltra nv can under
no circumstances whatsoever be held responsible for damage of whatever nature if the appliance was not
correctly installed according to the specified installation instructions, nor for damage as a result of unforeseen
circumstances such as natural disasters, lightning strike, etc. All such resulting costs are consequently at the
expense of the buyer and are not covered by the guarantee conditions.
Eltra nv, Pachtgoedstraat 2, 9140 Temse, Belgium, hereby declares that this product is in compliance with the
essential requirements and other relevant provisions of Directive R&TTE 1999/5/EC.The original declaration of
conformity can be requested at [email protected]
TECHNICAL SPECIFICATIONS
-
Required batteries heating controller (not included): 2 x 1,5V DC type AA
-
Required remote control battery: 12 VDC 1 x A23
-
Measured range: 0 ... 29.5°C
-
Setting range: 5 ... 28°C
-
Measurement accuracy: +/- 0.5°C
-
Temperature span: 1°C or 2°C adjustable
-
Measured cycle: 2 minutes
-
Ambient temperature: 0 ... 35°C
-
Storage temperature: -20 ... 70°C
-
Humidity: 5 ... 90% relative
-
Power consumption: Max. 100 mA
-
Standby power consumption: Max. 500 μA
-
Frequency: 433.92 MHz
-
Reception range: Max. 30 m
Summary of Contents for 423000078