8
Profibus Indicator Interface Installation and Programming Manual
3.0
Profibus Commands
The ProÞbus Indicator Interface uses 20-bit integer and 32-bit ßoating point commands to send and receive data
from the indicator. This section describes the input and output data formats, commands, and status bit
assignments, and provides examples of 20-bit and 32-bit command usage.
3.1
Integer (20-bit) Commands
3.1.1
Integer Command Formats
Tables 3-1 and 3-2 show the data formats used to send and receive 20-bit integer commands. Bit assignments as
follows:
R
Reserved
s00-s08
Status data
cccc cccc
Command number
v00–v19
20-bit integer value
See Table 3-3 on page 9 for a listed of supported commands; see Section 3.3 on page 12 for status bit
assignments.
NOTE
: Integer commands return no decimal point information to the master. For example, a value of 750.1
displayed on the indicator is returned to the master as 7501.
Bit
Byte 1
Byte 0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Word 0
R
R
R
R
R
R
R
R
c
c
c
c
c
c
c
c
Word 1
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Word 2
R
R
R
R
R
R
R
R
R
R
R
R
v19
v18
v17
v16
Word 3
v15
v14
v13
v12
v11
v10
v09
v08
v07
v06
v05
v04
v03
v02
v01
v00
Table 3-1. ProÞbus 20-bit Integer Output Format
Bit
Byte 1
Byte 0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Word 0
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Word 1
s15
s14
s13
s12
s11
s10
s09
s08
s07
s06
s05
s04
s03
s02
s01
s00
Word 2
R
R
R
R
R
R
R
R
R
R
R
R
v19
v18
v17
v16
Word 3
v15
v14
v13
v12
v11
v10
v09
v08
v07
v06
v05
v04
v03
v02
v01
v00
Table 3-2. ProÞbus 20-bit Integer Input Format