background image

contents

  1.  Introduction  ..........................................................................................................................  2

  2.  In general  .............................................................................................................................  2

  3.  Ranges of application  ..........................................................................................................  2

  4.  Installation  ...........................................................................................................................  3

  5.  Operation  .............................................................................................................................  3

  6.  Buttons and functional discription  ........................................................................................  4

  7.  Security tips  .........................................................................................................................  5

  8.  Servicing  ..............................................................................................................................  5

  9.  Guarantee regulations  .........................................................................................................  6

10 . Recognising and repairing of mistakes  ................................................................................  6

11.  Notes on Product Liability  ....................................................................................................  6

12.  Notes on Disposal  ...............................................................................................................  7

13.  EU Declaration of Conformity  ..............................................................................................  7

14.  Technical Data  ...................................................................................................................  16

2. in general

The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of 

technology, manufactured with much care and go under strict intensive controls.

The pumps have been optimized by us especially for the special requirements for circulating 

and fi ltering large volumes of water. Make sure after unpacking the pump that the data given 

on the type label agree with the included operating instructions. In the case of doubt the  pump 

is not to be used. Transport damages are immediately to be reported to the package distributor 

and to us in witten form.

3. rangeS of application

These pumps are made for pumping clear water (free of mud and sand, see technical data)

The pumps are made for the following ranges of application:

l

 In private and in public swimming pool

l

 Circulating large volumes of water

l

 Other Clear water pumping

2 English

Safety inStruction and WarningS

Please read the user manual 

before using the device

Pull power plug

Warning sign

Warning of electrical voltage

1. introduction

We would like to congratulate you on the purchase of our pump. We appreciate your trust. 

That‘s why funtional security and operational safety stands by us on fi rst place.

  

to prevent damage to persons or property, you should read this user manual 

carefully. please observe all safety precautions and instructions for proper use 

of the pump. failure to follow the instructions and safety precautions can result 

in injury or property damage.

  please keep this manual with the instructions and safety instructions carefully 

in order to at any time you can restore them. please always download the latest 

version of the user manual of www.profi -pumpe.de under „downloads“. This 

shall always prevail.

important!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any 

guarantee is void in case of improper use. They are not suitable for pumping fl ammable liquids 

or for use in places where there is danger of an explosion. The pumps are designed for home 

use in the house and garden. 

These pumps are intended for private use in the home and garden. These pumps are not desi-

gned for continuous use (without interruptions). In continuous operation mode, the lifetime will 

be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save 

the pump against dry running (install dry run protection). 

never start and stop the pump more than 20 times per hour. When the pump clocks, any 

claim under warranty is void.

not suitable for use with solar photovoltaic panels.

English 3

4. inStallation

 

The installation must be performed by a qualifi ed professional.

 

 Please, check each time before using, the electrical connections and the cables are not 

damaged. Check before the installation whether the electrical connections are earthed 

according to the statutory regulations and are installed. The pump is to be secured 

through a RCD circuit breaker with release current of 30 mA. is technically correct, so 

this warranty is void. It must be ensured that the pump is suffi ciently cooled during pro-

longed operation.

It is not recommended to perform even cable extensions or any other technical modifi cations. The 

lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibra-

tions from the pump or to the pump must be eliminated through appropriate actions (use of rubber 

buffers, braided hoses, line fi xation, etc.).

Do not reduce the suction line. All pipe/hose connections to and from the pump must be sealed. We 

recommend that you implement the suction line „as one piece“ without any interruption in order to 

prevent and avoid leaks. Check pump and water lines for leaks by pressure testing min. 24 hrs.

Is dirt expected  in the pump, an effective pre-fi lter should be installed before the pump inlet. Fill 

pump and suction

pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If neces-

sary, the pump and the suction line must be refi lled until a normal continuous operation has been 

established.

note: 

Please note that a tapering of the pump connections may cause a defect in the pump. Here, 

the terminal sizes specifi ed should be strictly adhered to. With strong restriction of fl owthrough on 

the pressure side of the pump (for example, due to clogged sand fi lter) water can come out of the 

housing.

5. operation

l

  Please remove the cover of the fi ller neck, fi ll in as much water as is necessary to allow it to 

escape from the fi ller neck, connect the hose sealingly after fi lling with water.

l

  If the pump is used for self-priming well water, make sure that a non-return valve is installed at 

the front end of the suction line.

l

  Connect the power supply, the display shows „0.0“ bar and the indicator light is on. 

l

  Pump works automatically. Then open the outlet valve in order to remove air from pipes.

l

 Start and stop the pump by press the button „

“ at any operation condition.

l

  By pressing the “ “ or “

“ key, the setpoint value of the working pressure can be set; a short 

press of the “ “ key increases the pressure by 0.1 bar each time. A short press of the “

“ but-

Summary of Contents for INVERT-YECH1

Page 1: ... PS01107 Technical changes misprints and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de operating inStructionS BedienungSanleitung de ...

Page 2: ... more than 5 minutes against a closed valve pump Save the pump against dry running install dry run protection never start and stop the pump more than 20 times per hour When the pump clocks any claim under warranty is void not suitable for use with solar photovoltaic panels English 3 4 inStallation The installation must be performed by a qualified professional Please check each time before using the...

Page 3: ...p button Press the button to start stop the pump and to recovery normal state manually when pump is in a state of water shortage 8 Decrease button Press the button one time can reduce 0 1 bar long time press will reduce rapidly 6 Buttons and functional discription 8 Servicing It must be regularly checked the pump filter and clean if necessary The service inter vals are based on the respective usag...

Page 4: ...our service platform http www profi pumpe de service php We will inform you how to proceed with case related Returns please sufficient postage Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery Our service we provide in Germany The warranty does not cover l Material wear sealing rings impeller wheels impeller chambers l Unjustified interventions or ...

Page 5: ...nweisungen und Sicherheitshinweise können zu körperlichen Schäden oder zu Sachschäden führen Bitte bewahren Sie die Bedienungsanleitung mit den anweisungen und Sicherheits hinweisen sorgfältig auf um jederzeit darauf zurückgreifen zu können Bitte laden Sie stets die neueste ausführung der Bedienungsanleitung von www profi pumpe de unter download herunter Diese ist stets maßgebend 4 inBetrieBnahme D...

Page 6: ...en Kopf Permanent Magnet motor Deckel Lüfter Ansaug seite Pumpen Gehäuse Druck Sensor Gummipuffer Auslass Ventil Drucktank LED Display Füllstutzen Druckseite Tastenfunktion und Display Beschreibung Nr NAME Beschreibung 1 Steigern Taste Ein kurzer Tastendruck erhöht den Druck um jeweils 0 1 bar das Halten der Taste bewirkt ein schnelles ansteigen des Drucks 2 Druck anzeige Zeigt die aktuellen Druck...

Page 7: ...esetzliche Gewährleistung In diesen Fällen überneh men wir den Umtausch oder die Reparatur der Pumpe Versandkosten werden von uns nur getragen soweit dies gesetzlich vorgeschrieben ist Im Garantiefall bitte über unsere Serviceplattform http www profi pumpe de service php den Fall an melden Dann teilen wir Ihnen die weitere Vorgehensweise fallbezogen mit Rücksendungen bitte ausreichend frankieren U...

Page 8: ...12 Notes Notizen 13 Notes Notizen ...

Page 9: ...ch PS01107 Power P1 Leistung P1 800 W Max pump capacity Max Fördermenge 3 7 m h Max pressure Max Druck 4 5 bar Max pump height Max Förderhöhe 45 m Max water temperature Max Wassertemperatur 60 C Protective class Schutzklasse IPX5 Tension Spannung 230V 50 Hz Measures in mm Maße in mm 300x187x282 Connection in out Anschlüsse 1 Cable length Kabellänge 1 5 m Schematic illustration as an example Please...

Reviews: