contents
1. Introduction .......................................................................................................................... 2
2. In general ............................................................................................................................. 2
3. Ranges of application .......................................................................................................... 2
4. Installation ........................................................................................................................... 3
5. Operation ............................................................................................................................. 3
6. Buttons and functional discription ........................................................................................ 4
7. Security tips ......................................................................................................................... 5
8. Servicing .............................................................................................................................. 5
9. Guarantee regulations ......................................................................................................... 6
10 . Recognising and repairing of mistakes ................................................................................ 6
11. Notes on Product Liability .................................................................................................... 6
12. Notes on Disposal ............................................................................................................... 7
13. EU Declaration of Conformity .............................................................................................. 7
14. Technical Data ................................................................................................................... 16
2. in general
The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of
technology, manufactured with much care and go under strict intensive controls.
The pumps have been optimized by us especially for the special requirements for circulating
and fi ltering large volumes of water. Make sure after unpacking the pump that the data given
on the type label agree with the included operating instructions. In the case of doubt the pump
is not to be used. Transport damages are immediately to be reported to the package distributor
and to us in witten form.
3. rangeS of application
These pumps are made for pumping clear water (free of mud and sand, see technical data)
The pumps are made for the following ranges of application:
l
In private and in public swimming pool
l
Circulating large volumes of water
l
Other Clear water pumping
2 English
Safety inStruction and WarningS
Please read the user manual
before using the device
Pull power plug
Warning sign
Warning of electrical voltage
1. introduction
We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That‘s why funtional security and operational safety stands by us on fi rst place.
to prevent damage to persons or property, you should read this user manual
carefully. please observe all safety precautions and instructions for proper use
of the pump. failure to follow the instructions and safety precautions can result
in injury or property damage.
please keep this manual with the instructions and safety instructions carefully
in order to at any time you can restore them. please always download the latest
version of the user manual of www.profi -pumpe.de under „downloads“. This
shall always prevail.
important!
The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any
guarantee is void in case of improper use. They are not suitable for pumping fl ammable liquids
or for use in places where there is danger of an explosion. The pumps are designed for home
use in the house and garden.
These pumps are intended for private use in the home and garden. These pumps are not desi-
gned for continuous use (without interruptions). In continuous operation mode, the lifetime will
be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save
the pump against dry running (install dry run protection).
never start and stop the pump more than 20 times per hour. When the pump clocks, any
claim under warranty is void.
not suitable for use with solar photovoltaic panels.
English 3
4. inStallation
The installation must be performed by a qualifi ed professional.
Please, check each time before using, the electrical connections and the cables are not
damaged. Check before the installation whether the electrical connections are earthed
according to the statutory regulations and are installed. The pump is to be secured
through a RCD circuit breaker with release current of 30 mA. is technically correct, so
this warranty is void. It must be ensured that the pump is suffi ciently cooled during pro-
longed operation.
It is not recommended to perform even cable extensions or any other technical modifi cations. The
lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibra-
tions from the pump or to the pump must be eliminated through appropriate actions (use of rubber
buffers, braided hoses, line fi xation, etc.).
Do not reduce the suction line. All pipe/hose connections to and from the pump must be sealed. We
recommend that you implement the suction line „as one piece“ without any interruption in order to
prevent and avoid leaks. Check pump and water lines for leaks by pressure testing min. 24 hrs.
Is dirt expected in the pump, an effective pre-fi lter should be installed before the pump inlet. Fill
pump and suction
pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If neces-
sary, the pump and the suction line must be refi lled until a normal continuous operation has been
established.
note:
Please note that a tapering of the pump connections may cause a defect in the pump. Here,
the terminal sizes specifi ed should be strictly adhered to. With strong restriction of fl owthrough on
the pressure side of the pump (for example, due to clogged sand fi lter) water can come out of the
housing.
5. operation
l
Please remove the cover of the fi ller neck, fi ll in as much water as is necessary to allow it to
escape from the fi ller neck, connect the hose sealingly after fi lling with water.
l
If the pump is used for self-priming well water, make sure that a non-return valve is installed at
the front end of the suction line.
l
Connect the power supply, the display shows „0.0“ bar and the indicator light is on.
l
Pump works automatically. Then open the outlet valve in order to remove air from pipes.
l
Start and stop the pump by press the button „
“ at any operation condition.
l
By pressing the “ “ or “
“ key, the setpoint value of the working pressure can be set; a short
press of the “ “ key increases the pressure by 0.1 bar each time. A short press of the “
“ but-