E-14
• Do not tighten the screws with too much force, since it can damage
the PS-A unit.
• The torque necessary to create a drip-resistant seal is 0.5 N•m.
• Depending on the installation panel's thickness, etc., the number of installa-
tion fasteners used may need to be increased to provide the desired level of
moisture resistance.
• Be sure to use installation fastener model CA3-ATFALL-01.
Attach the Installation Fasteners from Inside the Panel
The following figures show the eight (8) insertion slot locations of the PS-A
installation fasteners. Insert the hook section into the slot and tighten the fas-
tener with a screwdriver, as shown.
Insertion Slots
Top View
Bottom View
Right Side
Left Side
Create a Panel Cut
Insert the PS-A into the panel from the front.
under 4-R3[0.12]
Unit: mm [in.]
Panel
Panel thickness
1.6mm[0.06in] to
10mm[0.39in]
PS-A
383.5
[15.10 ]
+1
0
PS-A
Panel
+0.04
0
282.5
+1
0
+0.04
0
[1
1.12 ]
Installation
Fastener
Panel
PS-A