![PROEL PLLAS040 User Manual Download Page 14](http://html1.mh-extra.com/html/proel/pllas040/pllas040_user-manual_1609841014.webp)
14
BASIC SERVICE
Regular cleaning of the elements in the optical path, as well as the air vents, is vital to maintaining the
operational quality of the PLLAS040.
Important! Excessive dust, smoke fluid, and particulate build-up degrades performance and causes
overheating and damage to the fixture that is not covered by the warranty.
Cleaning the air vents:
To maintain adequate cooling, dust must be cleaned from the air vents periodically. Remove dust from
the air vents with a soft brush, cotton swab, vacuum, or compressed air.
Cleaning optical components:
Clean the optical components regularly. The presence of smudges or dust on optical surfaces can
reduce the strength of the light output and the quality of the effects.
Use care when cleaning optical components and work in a clean, well lit area. The coated surfaces are
fragile and easily scratched. Do not use solvents that can damage plastic or painted surfaces.
-
Disconnect the fixture from power and allow it to.
-
Remove upper cover.
-
Vacuum or gently blow away dust and loose particles with compressed air.
-
Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or
distilled water. Do not rub the surface: lift the particles off with a soft repeated press.
-
Remove smoke, and other, residues with cotton swabs or unscented tissues moistened with
isopropyl alcohol. A commercial glass cleaner may be used, but residues must be removed with
distilled water. Clean with a slow circular motion from center to edge. Dry with a clean, soft and lint-
free cloth or compressed air.
-
Close the fixture cover and tighten the thumb screw, taking care not to trap any loose wires.
TECHNICAL DATA
PLLAS040
Power supply:
DC 5V – 2A - (power supply included 100V-230V 50/60Hz)
Consumption: 10W
Laser:
30mW Green – 80mW Red
Led:
1x3W
blue
Dimensions: LxWxH
mm.210x160x170
Weight:
kg.
1,7