PROEL HPD2004 User Manual Download Page 2

FCC COMPLIANCE NOTICE

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void 

the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in 

a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed 

and used in accordance with the instruction manual, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of 

its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this 

from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should 

contact either the retailer where they purchased this product, or their local government office, for details of where and how they can 

take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the 

purchase contract. This product should not be mixed with other commercial wastes for disposal.

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated 

“dangerous voltage” within the product’s enclosure, that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance 

(servicing) instructions in the literature accompanying the appliance.

The information contained in this publication has been carefully prepared and checked. However no responsibility will be taken for any errors. All 

rights are reserved and this document cannot be copied, photocopied or reproduced in part or completely without written consent being obtained 

in advance from PROEL. PROEL reserves the right to make any aesthetic, functional or design modification to any of its products without any prior 

notice. PROEL assumes no responsibility for the use or application of the products or circuits described herein.

Il marchio riportato sul prodotto o sulla documentazione indica che il prodotto non deve essere smaltito con altri rifiuti domestici al 

termine del ciclo di vita. Per evitare eventuali danni all’ambiente si invita l’utente a separare questo prodotto da altri tipi di rifiuti e di 

riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali. Gli utenti domestici sono invitati a contattare 

il rivenditore presso il quale è stato acquistato il prodotto o l’ufficio locale preposto per tutte le informazioni relative alla raccolta 

differenziata e al riciclaggio per questo tipo di prodotto. Gli utenti aziendali sono invitati a contattare il proprio fornitore e verificare i 

termini e le condizioni del contratto di acquisto. Questo prodotto non deve essere smaltito unitamente ad altri rifiuti commerciali.

Il simbolo del lampo con freccia in un triangolo equilatero intende avvertire l'utilizzatore per la presenza di "tensioni pericolose" non isolate 

all'interno dell'involucro del prodotto, che possono avere una intensità sufficiente a costituire rischio di scossa elettrica alle persone.

Il punto esclamativo in un triangolo equilatero intende avvertire l'utilizzatore per la presenza di importanti istruzioni per l'utilizzo e la 

manutenzione nella documentazione che accompagna il prodotto.

Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per 

eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza 

previo consenso scritto della PROEL. PROEL si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche, funzionali o di 

design a ciascun proprio prodotto. PROEL non assume alcuna responsabilità sull’uso o sul l’applicazione dei prodotti o dei circuiti qui descritti.

Summary of Contents for HPD2004

Page 1: ...HPD2004 HPD4004 4 channel power amplifier USER MANUAL MANUALE D USO PROTECT BRIDGE ON LIMIT SIGNAL PROTECT LIMIT SIGNAL PROTECT BRIDGE ON LIMIT SIGNAL PROTECT LIMIT SIGNAL...

Page 2: ...constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instr...

Page 3: ...ale 35 dB 38 dB Gain fixed 32 dB 32 dB Guadagno fisso 32 dB 32 dB Input Impedance 30 Kohm bal 15 Kohm unbal Impedenza Ingresso 30 Kohm bilanciato 15 Kohm sbilanciato Input Connectors INPUT COMBO XLR F...

Page 4: ...AVO ALTOPARLANTE ENGLISH Loudspeaker Line Losses maximum permissible line lengths for 0 5dB losses voltage or spl ITALIANO Perdite di collegamento linee Altoparlanti massima lunghezza possibile per pe...

Page 5: ...bilanciato femmina LINK Balanced female XLR ground hot cold sleeve ground INPUT ingresso Jack bilanciato INPUT Jack balanced tip hot ring cold INPUT ingresso XLR bilanciato maschio INPUT Balanced male...

Page 6: ...SIGNAL PROTECT LIMIT SIGNAL PROTECT BRIDGE LIMIT PROTECT LIMIT FRONT PANEL FIG 4 PANNELLO FRONTALE FIG 4 DIMENSIONS FIG 4 DIMENSIONI FIG 4 48 3 cm 19 0 inch 43 4 cm 17 0 inch 36 7 cm 14 5 inch 8 9 cm...

Page 7: ...REAR PANEL FIG 5 PANNELLO POSTERIORE FIG 5...

Page 8: ...m a L R audio channels and set as HPF if used in combination with subwoofers or as stage monitors 1 1 R EXAMPLE A ESEMPIO A a2 a1 L 1 1 4 minimum 4 minimum 4 minimum 4 minimum set as STEREO for 4 indi...

Page 9: ...m set as PARALLEL for 2 channel pairs driven from a L R audio channels and set as BI AMP for 100Hz 24dB oct crossover frequency 1 1 1 1 1 1 R EXAMPLE C ESEMPIO C L 1 1 subwoofer 8 minimum subwoofer 8...

Page 10: ...equipment capable of producing high sound pressure levels use hearing protectors while the equipment is in operation Ear plugs or protectors in the ear canals or over the ears must be worn when operat...

Page 11: ...aired Proel S p A is not responsible for any direct damage or indirect damage caused by product defectiveness INSTALLATION AND DISCLAIMER Proel products have been expressly designed for audio applicat...

Page 12: ...onditions of use and therefore extensive durability The protection system includes thermal protection short circuit protection high frequency protection and CLIP LIMITER circuit INSTRUCTIONS 1 Power s...

Page 13: ...m using a loudspeaker processor in fact having a fixed gain the calculation of limiters is simplified See the manual of your loudspeaker processor for details 12 STEREO BRIDGE PARALLEL Allows the sele...

Page 14: ...POSITIVE output of Channel 2 4 PIN 1 connected to NEGATIVE output of Channel 2 4 PIN 2 and 2 NOT connected This is the amplified output of the signal applied to channel 2 4 input if the amplifier is...

Page 15: ...rto periodo di tempo Come suggerimento viene riportata la tabella dei tempi massimi di esposizione giornaliera al rumore al fine di evitare perdite di udito fonte della tabella l ente per la salute de...

Page 16: ...lusivamente ad un utilizzo specifico di tipo sonoro segnali di ingresso di tipo audio 20Hz 20kHz Proel declina ogni responsabilit per danni a terzi causati da mancata manutenzione manomissioni uso imp...

Page 17: ...ne in qualsiasi condizione d uso e una lunga durata nel tempo Il sistema di protezioni include protezione termica protezione sul corto circuito protezione in alta frequenza e circuito di CLIP LIMITER...

Page 18: ...no di 32dB 40x la sua sensibilit 5dBu 1 38Vrms NOTA Il guadagno fisso a 32dB una caratteristica utile per l impostazione di sistemi complessi di altoparlanti con processore in quanto con un gain fisso...

Page 19: ...schio collegato come segue PIN 1 collegato all uscita POSITIVA del canale 2 4 PIN 1 collegato all uscita NEGATIVA del canale 2 4 PIN 2 PIN 2 non collegati Questa l uscita amplificata del segnale appli...

Page 20: ...REV 28 15 CODE 96MAN0083 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com...