Output Limiters
High performance digital limiters are provided for each output with control over attack time,
release time and threshold level parameters - see page 23 for details. This level of control
allows the user to balance the required subjective quality of the limiter against the driver
protection requirements. It does also mean that an incorrectly set limiter may sound awful!
In particular, as with all limiters, using too fast an attack or release time will result in
excessive low frequency distortion. In the ‘Design a Xover’ sub-menu there is an option for
automatic limiter time constants.
In this mode the time constants will be automatically set from the Highpass filter frequency
according to the table below.
The time constants are set by the high pass filter frequency for that channel.
High Pass Filter
Auto Attack Time
Release Time
<10Hz – 31Hz
45mS
x16 (720mS)
31Hz – 63Hz
16mS
x16 (256mS)
63Hz – 125Hz
8mS
x16 (128mS)
125Hz – 250Hz
4mS
x16 (64mS)
250Hz – 500Hz
2mS
x16 (32mS)
500Hz - 1kHz
1mS
x16 (16mS)
1kHz – 2kHz
0.5mS
x16 (8mS)
2kHz – 22kHz
0.3mS
x16 (4mS)