PROEL AMP240V4 Instruction Manual Download Page 31

 

31

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for AMP240V4

Page 1: ...MANUALE UTENTE INSTRUCTION MANUAL Amplificatore Mixer a Quattro Zone Four Zones Control Mixing Amplifier AMP240V4...

Page 2: ...2...

Page 3: ...SO 4 2 DESCRIZIONE 6 3 FUNZIONI E CONTROLLI PANNELLO FRONTALE 7 4 FUNZIONI E CONTROLLI PANNELLO POSTERIORE 8 5 INSTALLAZIONE 11 6 ESEMPI DI POSSIBILI CONNESSIONI 14 7 CARATTERISTICHE TECNICHE 15 8 CON...

Page 4: ...e non interferisca con l adeguata ventilazione Per esempio l apparecchio non deve essere collocato su un letto copri divano o superfici simili che possono bloccare le aperture di ventilazione o posto...

Page 5: ...o al di l di quanto descritto nelle istruzioni di funzionamento Ogni altra riparazione deve essere affidata a personale specializzato IMPORTANTI NORME DI SICUREZZA Installare seguendo le istruzioni Il...

Page 6: ...ngressi MIC LINE con XLR Jack 6 3mm combinati Alimentazione 24V phantom sui 4 ingressi MIC Ingresso MIC1 con funzione priorit ad attivazione vocale VOX Un uscita PRE OUT Un ingresso AMP IN Un ingresso...

Page 7: ...eso tra 20 dB e 0 dB indicati dall accensione dei primi 5 leds se il livello di volume tale da far accendere gli ultimi 2 leds 3 dB 6 dB il segnale in uscita potrebbe risultare distorto e il volume do...

Page 8: ...Hz Fusibile T 6 3 AL AC 250V 3 Selettore per alimentazione di rete 230 117V CA 50 60Hz 4 INPUT 1 INPUT 4 a Selettore sensibilit d ingresso b Ingresso Mic Line tipo COMBO XLR female Jack 6 3 bilanciato...

Page 9: ...X INPUT 5 Le prese R e L consentono l ingresso del canale destro R e sinistro L attraverso connettori RCA A questo ingresso stereo possibile collegare una sorgente sonora esterna 6 MUTE SEN La funzion...

Page 10: ...usori tra COM e 100V nella zona desiderata 12 MOH OUTPUT 1W 8 Music On Hold Output Uscita monitor del segnale presente in INPUT 5 Consente il collegamento di un altoparlante monitor pilotato dall unit...

Page 11: ...tore PHANTOM a ON fig 2 rif 4 CONNESSIONE D INGRESSO LINE CD TUNE ecc In caso di lunghe tratte utilizzare il cavo schermato Riferendosi alla fig 1 rif 4 Regolare opportunamente il livello dell Ingress...

Page 12: ...denza costante 4 collegare i due terminali rispettivamente al morsetto COM e a quello contrassegnato con valore di impedenza desiderato Al fine di garantire il massimo rendimento l impedenza totale de...

Page 13: ...zona prescelto fig 2 rif 11 Quando si utilizza il selettore di zona non possibile utilizzare altoparlanti a impedenza costante in quanto la linea predefinita con tensione a 100 V Gli altoparlanti devo...

Page 14: ...14 6 ESEMPI DI POSSIBILI CONNESSIONI...

Page 15: ...ELEPHONE EMERGENCY Variable gain 600 ohm Signal Output PRE OUT normally connected to MAIN IN Output Levels PRE OUT 1V 600 MOH 0dBV 600 Variable level Controls 1 MASTER VOLUME CONTROL 4 MIC LINE VOLUME...

Page 16: ...16...

Page 17: ...MPORTANT SAFETY INSTRUCTIONS 18 2 DESCRIPTION 20 3 FRONT PANEL FUNCTIONS AND CONTROLS 21 4 REAR PANEL FUNCTIONS AND CONTROLS 22 5 INSTALLATION 25 6 CONNECTION EXAMPLE 28 7 TECHNICAL FEATURE 29 8 PACKA...

Page 18: ...UCTIONS Water and moisture This apparatus should not be used near water i e bathtub kitchen sink swimming pools etc Ventilation This apparatus should be placed in a position that doesn t interfere wit...

Page 19: ...rked change in performance If the product has been dropped or has been damaged in any way Maintenance The user shouldn t attempt maintenance not described in this user s manual All maintenance should...

Page 20: ...ce constant outputs 4 and constant voltage outputs 25 70 100 V Four MIC LINE combo XLR jack inputs 24V Phantom supply Vocal activating priority MIC1 input VOX PRE OUT output AMP IN input RCA input LIN...

Page 21: ...dB e 0 dB and when the first five leds are on If such level makes lighting only the first 2 leds 3 dB 6 dB the output signal could be distorted the volume then must be reduced 6 LEVEL ZONE 1 ZONE 5 Vo...

Page 22: ...60Hz Fusibile T 12 AL AC 250V 220 240 V 50 60Hz Fusibile T 6 3 AL AC 250V 3 Mains Selector 230 117 V AC 50 60 Hz 4 INPUT 1 INPUT 4 a Input sensitivity selectors b Balanced COMBO type MIC LINE input fe...

Page 23: ...microphones 5 AUX Input INPUT 5 R right and L left sockets allow to input right and left channels using RCA connectors It s possible to use this input for an external audio source 6 MUTE SEN The MUTE...

Page 24: ...ne terminal Zone 1 2 3 and 4 100V outputs output terminals Connect the speaker lines to the COM terminal and 100V to the desired terminal ZONE 12 MOH OUTPUT 1W 8 Music On Hold Output monitor output of...

Page 25: ...on position ON fig 2 ref 4 LINE INPUT CONNECTIONS CD AM FM TUNER etc use shielded cable for long distance Revert to fig 1 rif 4 set GAIN level and set PHANTOM switch on position ON fig 2 ref 4 For di...

Page 26: ...ance line To use this amplifier with a constant impedance line 4 please connect the COM terminal to the negative post of your speaker and connect the proper impedance terminal to the positive post To...

Page 27: ...the desired zone number fig 2 ref 11 If you re using a zone selector you won t be able to use constant impedance speakers since the line is set at 100 V constant voltage Speakers should have a transfo...

Page 28: ...28 6 CONNECTION EXAMPLE...

Page 29: ...LEPHONE EMERGENCY Variable gain 600 ohm Signal Output PRE OUT normally connected to MAIN IN Output Levels PRE OUT 1V 600 MOH 0dBV 600 Variable level Controls 1 MASTER VOLUME CONTROL 4 MIC LINE VOLUME...

Page 30: ..._______________________________________________________ ____________________________________________________________________________________________ ___________________________________________________...

Page 31: ...31...

Page 32: ...32 PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 E mail info proel com www proel com...

Reviews: