PRODIGIT
3260A Series Operation Manual 15
3.1.6 Lower 4-1/2 Digit Monitor
3.1.6.1
Under Preset OFF condition:
This monitor will be a 4 1/2 digit ammeter to display the load current
actually flowing into the electronic load.
3.1.6.2
Under Preset ON conditioin:
This monitor can display the set value of the front panel manual operation
or the set value upon remote control.
3.1.6.2.1 Display the set value of C.C. Level A and B under C.C.mode
with the unit as
〝
Arms
〞
.
3.1.6.2.2 Display the set value of C.R. Level A and B under C.R. mode
with the unit as
〝
Ω.
〞
3.1.6.2.3 Upon protection condition:
Upon over-current, over-power and over-temerature,
〝
oCP
〞
,
〝
oPP
〞
and
〝
oTP
〞
will be displayed respectively.
3.1.6.3
Under LIMIT ON condition:
3.1.6.3.1 Display the lower limit of voltmeter with the unit as
〝
Vrms
〞
.
3.1.6.3.2 Display the lower limit of ammeter with the unit as
〝
Arms
〞
.
3.1.6.3.3 Display the lower limit of Wattmeter with the unit as
〝
W
〞
3.1.6.3.4 Display the lower limit of VA meter with the unit as
〝
VA
〞
.
3.1.6.4 Under REEQ ON condition:
3.1.6.4.1 Under frequency setting function, monitor will display DC , 0.1
~
400.0 Hz.
3.1.6.4.2 Under bank selection function, monitor will display 0
~
10.
3.1.6.4.3 Under sync selection function, monitor will display
〝
ON
〞
,
〝
OFF
〞
.
3.1.7 PRES ON/OFF Key and LED Monitor
Depressing PRES Key will be ON, further depressing will be OFF, further depressing
will be ON again and so on. ON means Preset ON, e.g., to preset condition display to
ON. OFF means preset OFF, e.g., the condition is not preset and shall be the actual
condition of the voltage and current of the load.
Under Preset OFF condition, the upper 4 1/2 digit monitor displays the voltage input
to electronic load while the lower 4 1/2 digit monitor displays the current flowing into
electronic load with the unit as
〝
Vrms
〞
&
〝
Arms
〞
respectively and the unit indicator
will come on also.
Under Preset ON condition, PRES LED monitor is ON, both upper and lower 4 1/2
digit monitors will have different displays with the change of working mode as shown
below:
3.1.7.1
C.C.Mode:
The setting value of Level A / B load current can be displayed on the lower
4 1/2 digit monitor with the unit as
〝
Arms
〞
, LED indicator will be ON.
3.1.7.2 Linear C.C. Mode:
The setting value of Level A / B load current can be displayed on the lower
4 1/2 digit monitor with the unit as
〝
Arms
〞
, LED indicator will be ON.
3.1.7.3
C.R.Mode:
The setting value of Level A/B load resistance can be displayed on the
lower 4 1/2 digit monitor with the unit as
〝
Ω
〞
, LED indicator will be ON.