background image

 

Operating Manual ProDevice ASM120 PPMS USER

 

 

 

8

 

www.prodevice.eu

 

 

NOTE! 

 

After installing the software package, it is recommended to check that 

the .NET Framework component of the workstation OS is up to date with the 

latest version. Installing the .NET Framework package version 4.0 or higher 

may require installing additional operating system components, as required by 

Microsoft Corp.

 

If the user does not customise the installation, the ProDevice ASM120 

PPMS USER software package is installed in the following default location: 

C:\Program Files\ProDevice\PPMS user

.

 

Installation of the package creates the quick launch shortcut on the work 

station's desktop. The software shortcut is also installed in the 

Start Menu

 of 

the work station operating system.

 

 

 

Fig. 3.6 The Start Menu of the operating system with the shortcut to the 

ProDevice ASM120 PPMS USER package 

The software delivered with the device is intended for the particular serial 

number of the device. 

Summary of Contents for ASM 120

Page 1: ...OPERATING MANUAL PPMS USER software tool package for ProDevice ASM120 version 10 0 www prodevice eu...

Page 2: ...e and hardware requirements 5 Installation of the software package 5 Launching the software 9 Working with the software 11 Menu 11 Communication 12 Status 14 Reports 16 IP settings 22 Time date 24 Aut...

Page 3: ...permissible number of data removal cycles after which the device is automatically locked The customers who rent the degausser can remotely charge the device for a certain number of removal cycles This...

Page 4: ...oft NET Framework Client Profile version 4 0 or higher or Microsoft Framework version 4 0 or higher 3 INSTALLATION OF THE SOFTWARE PACKAGE Install the ProDevice ASM120 Admin software package by launch...

Page 5: ...Operating Manual ProDevice ASM120 PPMS USER 6 www prodevice eu Fig 3 2 Disk path selection window for the software package Fig 3 3 Settings confirmation window for the software installation process...

Page 6: ...Operating Manual ProDevice ASM120 PPMS USER ASM120 www prodevice eu 7 Fig 3 4 Product installation progress window Fig 3 5 Software installation finish window...

Page 7: ...rp If the user does not customise the installation the ProDevice ASM120 PPMS USER software package is installed in the following default location C Program Files ProDevice PPMS user Installation of th...

Page 8: ...w settings IP Address 192 168 0 190 Subnet mask 255 255 255 0 Default gateway 192 168 0 1 Click OK to confirm changes after entering the data Only now will the computer correctly communicate with the...

Page 9: ...ically attempt to connect with the device This process will be seen in the message Trying to connect in the status line at the bottom of the software interface The connection test is repeated until co...

Page 10: ...can access a set of function buttons grouped in the Menu area The buttons display specific function screens of the software Fig 4 1 1 Software Menu The Menu area features the following buttons Commun...

Page 11: ...TION The function screen for establishing and configuring up the network connection with the device Fig 4 1 2 1 Communication function screen Fig 4 1 2 1 Communication function screen The screen has f...

Page 12: ...ch act as follows Fig 4 1 2 3 The Communication screen function buttons Reconnect this button initiates the connection with the device which has the IP stated in the IP field over the TCP IP port in t...

Page 13: ...ing Manual ProDevice ASM120 PPMS USER 14 www prodevice eu 4 1 3 STATUS The function screen which displays the information on the status parameters of the device Fig 4 1 3 1 Degausser Status function s...

Page 14: ...ield displays the current value of the device Cycle Counter Cycle count to inspect this field displays the current cycle count remaining to the next presumed service inspection of the device Blockade...

Page 15: ...assword the device received the command to change the Device Password an additional parameter stores the new password access level Administrator Set blockade counter the device received the command to...

Page 16: ...peak value access level Customer No pulse the device did not record the magnetic pulse despite the trigger servicing is required access level Customer Set the non erasable counter the device received...

Page 17: ...leted cycle start the completed cycle number from the non erasable counter the measured value of the erasing cycle in the form of magnetic induction in the area in which the erased element is placed F...

Page 18: ...ig 4 1 4 3 The Simplified Report screen function buttons New this function button allows generating a new report of the events recorded by the device The button remains disabled until correct communic...

Page 19: ...nication is established with the device Print to PDF this button generates the report in the pdf file format The opened dialogue window allows naming the new report and selecting the disk path to whic...

Page 20: ...date of generation The information given in the report are presented in a table The table columns read the full date and time from the device clock at which the event was recorded the cycle number fro...

Page 21: ...TINGS The function screen which allows changing the current IP address of the device Fig 4 1 5 1 Degausser settings function screen Fig 4 1 5 1 Degausser IP function screen The screen has fields with...

Page 22: ...lished The user cannot edit this field New IP this field is used to enter the new IP address to be assigned to the device The user can edit this field The entered field value is validated Until the IP...

Page 23: ...4 www prodevice eu 4 1 6 TIME DATE The function screen which allows adjusting the date and time of the device clock Fig 4 1 6 1 Date Time function screen The screen has fields with the following prope...

Page 24: ...screen remain disabled until correct communication is established with the device REMOTE CHANGE OF THE BLOCKADE STEP BY STEP INSTRUCTIONS If the Customer uses the preset limit of removal cycles they...

Page 25: ...ator who uses it in the application to generate the Authorisation File which contains the information about the new blockade counter value the device identification data and the information which enab...

Page 26: ...ing the save location of the generated file click SAVE 4 Send the generated file to the device Administrator with the information about the number of required additional removal cycles 5 The Administr...

Page 27: ...which act as follows Fig 4 1 7 3 The Authorisation screen function buttons Load this button allows loading the Authorisation File created by the device Administrator Use the button to open the system...

Page 28: ...the necessary service inspection MAC address the MAC address of the device which is also assumed as the device serial number IP address the IP address of the device used to communicate with the machi...

Page 29: ...ate the Key File which enables setting the cycle count blockade of the device based on the Authorisation File for blockade setting Check the device RTC Check the selected parameters of the device Cont...

Page 30: ...milar situations e g during loading of the Key File to set the blockade Error when saving file this message is displayed in a new dialogue window This means that the Key File saving is incorrect File...

Page 31: ...and tel no 48 12 379 30 30 e mail info prodevice eu customer service serwis prodevice eu If you wish to customise a device or the software add a new interface language or if you have other suggestions...

Reviews: