14/48
2009/02 - Indice de révision : I - Code : 0033035
INSTALLATION OF THE HEAT EXCHANGER
- Heat exchangers must be installed in accordance with the rules of the art and the standards in effect.
- The heat exchanger should be installed as close as possible to the boiler in order to minimise heat loss. If this is
not possible, you will need to lag the primary circuit pipes with thermal insulation.
- For optimum heat exchange, the flows in the primary circuit and secondary circuit must cross within the exchanger.
- The heat exchanger must be connected directly to the boiler’s hot water production system. It should under no
circumstances be plumbed into an existing network (radiator circuit, residential hot water supply circuit, etc.)
- To mount the heat exchanger, use the support plate as a template to mark out the 4 holes that need to be drilled
in the wall.
By-pass
Filter
Boiler
Buffer tank
From the boiler
Primary circuit (to the boiler)
CLIMEXEL heat exchanger
screwed
PVC Union
or
solvent
or
solvent
PVC Union
screwed
Valve
Pump
Suction
Retun
Water
treatment
S
e
condar
y cir
cuit (t
o the pool)
HYDRAULIC CONNECTIONS
S
CHEMATIC DIAGRAM OF A STANDARD
INSTALLATION
INSTALLATION SITE
The heat exchanger was originally designed for a pool water flow from left to right.
The water from the boiler enters from the left, flows through the heat exchanger in the opposite direction to the
pool water and exits on the same side lower down.
The temperature sensor is inserted into the recess on the left-hand side of the heat exchanger (at the pool water
entry point).
To invert the direction of water flow, do the following :
- Unscrew both of the 3 part unions on the circulator and invert them. Screw the 3 part unions back together.
- Take the temperature sensor out of the housing on the left-hand recess and insert it into the corresponding
recess on the right hand side.
Summary of Contents for Climexel 9200200
Page 6: ...6 48 2009 02 Indice de révision I Code 0033035 CARACTERISTIQUES TECHNIQUES ...
Page 7: ...7 48 2009 02 Indice de révision I Code 0033035 ...
Page 8: ...8 48 2009 02 Indice de révision I Code 0033035 ...
Page 11: ...11 48 2009 02 Indice de révision I Code 0033035 Notes ...
Page 23: ...23 48 2009 02 Indice de révision I Code 0033035 Notes ...
Page 35: ...35 48 2009 02 Indice de révision I Code 0033035 Notes Anmerkungen ...
Page 36: ...36 48 2009 02 Indice de révision I Code 0033035 2009 02 Indice de révision I Code 0033035 ...