12/24
2014/04 - Indice de révision : F - Code : 0026650
11
12
- Insert the o-ring into the groove cut into the outer edge of the lid.
- Check that the upper, inner section of the tank and the seal around the lid are clean.
- Remove the plug from the collector pipe and fit the lid onto the tank. The collector pipe should fit into the
diffuser under the lid.
- Put the lid in place following the instructions provided on the following page.
- Using the ring, assemble the lid and tank. Tighten firmly by hand only.
9
10
Mounting the diffuser:
Centre the diffuser in its housing, and push it
firmly against the lid, twist it to slide the tongue
of the diffuser fully into the U shaped groove in
the lid.
7
8
Position the pressure gauge correctly and
place it in its housing.
Installing the pressure gauge:
Place the o-ring in its groove in the cover.
Working from underneath the cover, tighten the
bronze nut by hand, then moderately using a
22 tube wrench. Take care not to damage the
o-ring.