Procom WAN18N-2 Manual Download Page 6

www.usaprocom.com

200064-01A

6

AIR FOR COMBUSTION AND VENTILATION

 WARNING: If the area in which 

the heater may be operated does 

not meet the required volume for 

indoor combustion air, combus-

tion and ventilation air shall be 

provided by one of the methods 

described in the National Fuel 

Gas Code, ANSI Z223.1/NFPA 

54, the International Fuel Gas 

Code, or applicable local codes.

Today's homes are built more energy efficient 

than ever. New materials, increased insula

-

tion,  and  new  construction  methods  help 

reduce  heat  loss  in  homes.  Home  owners 

weather strip and caulk around windows and 

doors to keep the cold air out and the warm air 

in. During heating months, home owners want 

their homes as airtight as possible.
While it is good to make your home energy 

efficient, your home needs to breathe. Fresh 

air must enter your home. All fuel-burning ap

-

pliances need fresh air for proper combustion 

and ventilation.
Exhaust fans, fireplaces, clothes dryers, and 

fuel  burning  appliances  draw  air  from  the 

house to operate. You must provide adequate 

fresh air for these appliances. This will en

-

sure  proper  venting  of  vented  fuel-burning 

appliances.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo-

sote, ashes, and loose paint by 

a qualified chimney cleaner. 

Creosote will ignite if highly 

heated. A dirty chimney flue may 

create and distribute soot within 

the house. Inspect chimney flue 

for damage.

NOTICE:  Installation,  service,  and  repair 

of  this  appliance  must  be  performed  by  a 

qualified installer, service agency, company 

or gas supplier experienced with this type of 

gas appliance. Only factory authorized com

-

ponents listed in these instructions may be 

used in accordance with the manufacturer's 

instructions and all codes and requirements 

of  the  authority  having  jurisdiction. Any 

modifications to this kit, or use of unauthorized 

components, or accessory items, will void the 

manufacturer's warranty, and may result in a 

hazardous condition.

INSTALLATION

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must install On/Off Safety Pilot 

Valve Kit (see 

Accessories

, page 12).

If the fireplace does not have a gas supply shutoff valve, one must be installed.

The fireplace chimney flue and vent must be 

drafting properly. To check the vent for proper 

drafting,  light  a  tightly  rolled  newspaper  on 

one end and place it at the inside front edge of 

the fireplace. Observe the smoke and be sure 

the vent is properly drawing it up the chimney. 

If the smoke spills out into the room, extin

-

guish the flame and remove any obstruction 

until proper venting is achieved. The chimney 

flue  must  remain  open  a  minimum  of  3"  at 

all times during the operation of this log set.

VENTING SPECIFICATIONS FOR INSTALLATION

Summary of Contents for WAN18N-2

Page 1: ...and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immed...

Page 2: ...ntenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer service ag...

Page 3: ...um 13 W C Add 4 when using ON OFF safety pilot valve kit For use if unit is converted to Propane LP gas SAFETY IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op era...

Page 4: ...ing and the burning of manufacturing residues You may wish to add more ventilation by opening a window SAFETY 7 To reduce the creation of soot follow the instructions in Care and Maintenance page 15 8...

Page 5: ...llation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchase...

Page 6: ...ied chimney cleaner Creosote will ignite if highly heated Adirtychimneyfluemay createanddistributesootwithin the house Inspect chimney flue for damage NOTICE Installation service and repair of this ap...

Page 7: ...s Supply page 8 Gas line is on the left side If your gas line will be coming into the fireplace from the left side continue with step 2 2 Using a screwdriver remove cover plate on left side of burner...

Page 8: ...ter or greater to allow proper gas volume to log set If pipe is too small loss of pres sure will occur Installation must include an equipment shut off valve union and plugged 1 8 NPT tap Locate NPT ta...

Page 9: ...d 3 Pressurize supply piping system by either using compressed air or opening gas sup ply tank valve 4 Check all joints of gas supply piping sys tem Apply a noncorrosive leak detection fluid to gas jo...

Page 10: ...NING Failure to posi tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury It is very im...

Page 11: ...uctions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t t...

Page 12: ...curing of the logs Ignite a 2 flame and maintain it for 1 hour Burn the logs in consecutive 1 hour periods raising the flame an additional 2 to full flame height for a total of three hours CARE AND M...

Page 13: ...ective Action Log set is smoking soot ing excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of car bon soot where flames contact the logs 1 Poor fuel qu...

Page 14: ...alve Gas odor during com bustion 1 Gas leak See Warning statement at top of page 16 1 Locate and correct all leaks see Checking Gas Connec tions page 9 TROUBLESHOOTING REPLACEMENT PARTS Contact author...

Page 15: ...rs 1 WAN300B Hardware Package 1 WAL08 02 1 2 Female x 5 8 Flare Adapter 1 WAL13 01 Damper Clamp 1 ITEM PART DESCRIPTION QTY 1 BL050 01 3 8 Female x 5 8 Flare Adapter 1 2 WAL06 01 Injector Mounting 1 3...

Page 16: ...ller in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and...