GROUNDING INSTRUCTIONS 

COMANCHE 86038890  03/20/07 

 

2-3

THIS PRODUCT IS FOR COMMERCIAL USE 
ONLY.

 

ELECTRICAL:

 

In the USA  this machine operates on a 
standard 15 amp 115V, 60 hz,  A.C. power 
circuit . The amp,  hertz, and voltage are listed 
on the data label found on each machine.  
Using voltages above or below those indicated 
on the data label will cause serious damage to 
the motors.

  

EXTENSION CORDS: 

If an extension cord is used, the wire size must 
be at least one size larger than the power cord 
on the machine, and must be limited to 50 feet 
(15.5m) in length. 

GROUNDING INSTRUCTIONS:

 

This appliance must be grounded.  If it should 
malfunction or break down, grounding provides 
a path of least resistance for electric current to 
reduce the risk of electric shock.  This 
appliance is equipped with a cord having an 
equipment-grounding conductor and grounding 
plug.  The plug must be inserted into an 
appropriate outlet that is properly installed and 
grounded in accordance with all local codes 
and ordinances.  
 
This appliance is for use on a nominal 120-volt 
circuit, and has a grounded plug that looks like 
the plug in “Fig. A”.  A temporary adaptor that 
looks like the adaptor in “Fig . C”  may be used 
to connect this plug to a 2-pole receptacle as 
shown in “Fig. B”, if a properly grounded outlet 
is not available.  The temporary adaptor should 
be used only until a properly grounded outlet 
(Fig. A) can be installed by a qualified 
electrician.  The green colored rigid ear, lug, or  
wire extending from the adaptor must be 
connected to a permanent ground such as a 
properly grounded outlet box cover.  Whenever 
the adaptor is used, it must be held in place by 
a metal screw. 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock.  Check with a qualified 
electrician or service person if you are in 
doubt as to whether  the outlet is properly 
grounded.  Do not modify the plug provided 
with the appliance - if it will not fit the outlet, 
have a proper outlet installed by a qualified 
electrician.

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Comanche 10075270

Page 1: ...MODELS CM1 10075270 CM2 10075290 CM2H 10075310 Operating Instructions 86038890 06 09 09 PRV NO 98929 R PORTABLE EXTRACTOR Read these instructions before using the machine...

Page 2: ...___________________________________________________________ Phone Number _________________________________________________________________________________________ MODEL _______________________________...

Page 3: ...and Storage 3 4 MAINTENANCE Daily Maintenance 4 1 Periodic Maintenance 4 1 Monthly Maintenance 4 1 Semi annually 4 1 Lubrication 4 1 Storage 4 1 Solution Pump Replacement 4 2 Vacuum Motor Replacement...

Page 4: ...PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the part...

Page 5: ...st or vapors This machine is suitable for commercial use for example in hotels schools hospitals factories shops and offices for more than normal housekeeping purposes Maintenance and repairs must be...

Page 6: ...afe operation of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentiall...

Page 7: ...let that is properly installed and grounded in accordance with all local codes and ordinances This appliance is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug i...

Page 8: ...Electrical 115V 60HZ Electric Vacuum Motor DUAL 2 STAGE Solution Pump 100PSI Solution Capacity 10 gal 38L Recovery Capacity 10 gal 38L Dimensions Weight Empty 81 lbs 37kgs Dimensions Length 31 in 78 7...

Page 9: ...86038890 03 20 07 3 2 Vacuum Inlet Solution Outlet Solution Tank Vacuum 2 Vacuum 1 Vacuum Tank Water Pump Heater Optional Accessory 10073510 PRV NO CM2H standard option Base Assembly Dump Valve Soluti...

Page 10: ...NING EMPTYING TANKS Always use defoamer if foaming occurs Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum motor without activating the float shutoff 1...

Page 11: ...by the cleaning chemicals NOTE Dispose of waste in a proper manner which would not violate any Local State or Federal law 3 Run a small amount of clean water through pump if chemicals were used This w...

Page 12: ...s covers removed to allow tanks to dry PERIODIC MAINTENANCE 1 Twice a month flush a white vinegar solution one quart vinegar to two gallons water or anti browning solution mixed as directed through th...

Page 13: ...tor is grooved extremely pitted or not concentric the motor will need to be replaced or sent to a qualified service center Important These brushes wear quicker as the length shortens due to increased...

Page 14: ...with Superlube 6 Reassemble regulator 7 With pump ON re adjust pressure regulator for normal operation LUBRICATE U CUP WITH SUPERLUBE MONTHLY P IS T O N S P R IN G R E T A IN E R P L A T E S P R IN G...

Page 15: ...open valve on cleaning wand to relieve air Pump runs no solution Internal or external solution line damaged and leaking Replace Internal pump components wearing out Replace see pump kit components Pg...

Reviews: