40
Operations
Upholstery Cleaning
Upholstery tool, (See Options section)
1.
To protect fabrics, reduce solution temperature as
needed by opening the solution temperature
control valve on the lower front panel. Engine
speed may also be reduced slightly to reduce heat
and vacuum.
Shutdown And Daily Maintenance
1.
Close chemical metering valve.
2.
Allow the unit to run for 2 minutes with the vacuum
hose disconnected to remove moisture. Spray
water displacing lubricant into the vacuum lubrica-
tion cup and cover the vacuum inlet to draw the
water displacing lubricant into the blower. This will
prevent corrosion due to moisture.
3.
Set engine throttle at idle position and allow the
water temperature to cool down, utilizing the tem-
perature control valve in the open position to bleed
off residual hot water left in the system.
4.
Close temperature control valve and turn off igni-
tion switch.
5.
Disconnect all hoses and tools.
6.
Drain waste tank and rinse with clean water.
De-Flooding Operations
De-flooding operations involve removal of water from
carpet and flooring. This differs from normal cleaning
operations in that no water or solution is required. An
automatic waste pump-out is highly recommended for
all de-flooding operations due to the large amount of
water removal often required.
1.
Move the solution temperature control lever from
the "hot" position to the "warm" position.
2.
Ensure that the solution pump switch is in the OFF
position.
3.
Operate with all side and rear cargo doors open.
Freezing Protection
If the unit is exposed to freezing weather the water
in the unit may freeze, causing SERIOUS DAMAGE to
the unit. To avoid this, the following is recommended
during the cold weather season
.
Si l'appareil est exposé au gel, l'eau dans l'appareil
risque de geler, causant ainsi des DOMMAGES
MAJEURS à l'appareil. Pour éviter une telle situa-
tion, il est recommandé de faire ce qui suit durant la
saison froide.
When the unit is not in use, always park it in a heated
building.
While in operation, avoid long shutdowns as the unit
provides heat while running. Shut it down just prior to
leaving for the next job.
If a heated building is not available, we recommend that
you winterize the unit with anti-freeze. At present, it is
only possible to winterize units, which do not have an
auxiliary water tank. Units with auxiliary water tanks
must be stored in a heated building when not in use.
86410220 Operators Manual - Apex GTX Prochem
Summary of Contents for APEX GTX 1.001-139.0
Page 2: ......
Page 15: ...13 Notes 86410220 Operators Manual Apex GTX Prochem...
Page 25: ...23 Notes 86410220 Operators Manual Apex GTX Prochem...
Page 62: ......
Page 70: ...8 Side Panel Right 1 3 4 2 86410230 Spare Parts List APEX GTX Prochem...
Page 80: ...18 Control Panel Mounting 2 1 3 86410230 Spare Parts List APEX GTX Prochem...
Page 86: ...24 Engine Mounting 5 6 4 3 6 5 7 6 5 7 9 2 1 8 86410230 Spare Parts List APEX GTX Prochem...
Page 90: ...28 Coolant System 86410230 Spare Parts List APEX GTX Prochem...
Page 92: ...30 Vacuum Pump 86410230 Spare Parts List APEX GTX Prochem...
Page 96: ...34 Solution Pump 86410230 Spare Parts List APEX GTX Prochem...
Page 106: ...44 Helicoil 86410230 Spare Parts List APEX GTX Prochem 10 9 3 13 12 1 4 2 5 8 5 7 6 11...
Page 124: ...62 Battery Floor Mount 10 9 8 7 6 5 4 3 1 2 86410230 Spare Parts List APEX GTX Prochem...
Page 126: ...64 Chemical Jug Floor Mount 5 2 4 1 6 3 86410230 Spare Parts List APEX GTX Prochem...
Page 132: ...70 Notes 86410230 Spare Parts List APEX GTX Prochem...
Page 133: ...71 Options OPTIONS 86410230 Spare Parts List APEX GTX Prochem...
Page 136: ...74 Exhaust Optional 2 3 4 1 5 86410230 Spare Parts List APEX GTX Prochem...