M-43-01
Lufran Single Outlet Manual
Revision - Date: 08 – 04/06/15
- 98 -
Spare Parts (Continued):
Additional Spare Parts for Specific Units:
Process
Technology
Part #
Part for the
Following
Wattage
Units:
Description
Qty
**
FUSE: high voltage power distribution
(Refer to page 1 of the electrical prints for the specific part
number of these fuses.)
3
**
HEATER: replacement heating column
(Refer to label on heating column for the specific model
number of this part)
1
TC-L-KT-15
65, 72,
130, 144
SENSOR: heating column water temperature, J-type
thermocouple, one sensor per column
2
TC-L-KT
52, 105,
(72kW, 208V)
SENSOR: heating column water temperature, J-type
thermocouple, one sensor per column
1
Recommendations:
1) One complete spare parts kit is sufficient for every 4 to 6 Lufran fluoropolymer inline
water heaters installed in a single location. Be sure to immediately reorder any parts
that are used.
2) Sensors for the inlet/outlet process water (Part # TC-DI-L-2.25) are a required spare
part for each DI Heating Column.
Note
: Quantities may vary depending on the number of heating columns in a particular
unit.