M-43-01
Lufran Single Outlet Manual
Revision - Date: 08 – 04/06/15
- 36 -
Operations Menu:
The operations menu provides current performance statistics of the Lufran
fluoropolymer inline water heater. It is the default menu that appears following the
startup screen. The navigation keys at the bottom of the screen provide access to the
other menus available.
Operations Menu
Information Panel
Description
HEATER GRAPH
This button will go directly to a display that charts the current
temperature performance of the heater.
INLET TEMPERATURE
This value is the temperature measured from the process sensor
located at the inlet of the heater.
FLOW RATE
This value Is the water flow rate measurement taken from the
internal flow meter.
PROCESS SETPOINT
This button will display the current temperature outlet setting. The
operator can change this value by pressing the button. A numeric
keypad will appear to allow the operator to enter a new setpoint
value. The operator must press ENTER (
◄┘
)
on the keypad in
order to save the new value.
OUTLET
TEMPERATURE
This value is the temperature measured from the process sensor
located at the outlet of the heater.
HEATER OUTPUT %
This value shows the output load of the heating elements needed at
that specific time in order to provide the desired outlet temperature.
Figure 21: Operations Menu