background image

 

 

 

 
27. October 2020 

© Copyright 2020, PROCEQ SA 

 

Make sure that the batteries are inserted in the correct direction of polarity, there is a check-up drawing 
located near the battery lid (below): 
 

 

 

Study the overview of the battery compartment with the lid removed. The visible ends of the inserted 
batteries should correspond to the ones in the drawing next to it 
(+ being the one with the knob, - being the more flat-ended one.) 
 
When packing up the RQ8000 to its carrying case for transporting the measurement system to another 
location it is advised that the batteries should be removed from the battery slot and packed separately. 
This way the measurement device does not switch on by accident resulting in lowered charge or drained 
batteries  and  also  the  rechargeable  batteries  have  a  lower  risk  of  self-discharging.  This  is  also  the 
recommended  procedure  when  the  measurement  device  is  going  be  left  alone  in  storage  for  longer 
periods of time. 
 
With the batteries removed the real-time clock of the RQ8000 device loses the correct time in 2-4 weeks. 
If  this  is  the  case  it  is  recommended  that  the  RQ8000  is  connected  to  the  PC  before  making  a 
measurement. By doing this the correct time is set and the timestamps of the measured files are correct. 
 

3.2.2  Recharging Batteries 

 

There are two methods of keeping RQ8000 batteries loaded and ready for measurement.  
Every RQ8000 unit is supplied with an 

external battery charger

 which allows the user to recharge the 

batteries outside the RQ8000 unit. When using an external charger to charge your batteries make sure 
that you charge them to full capacity before inserting them back to the RQ8000. 
 
Another method is the 

USB charge

. When the RQ8000 is connected to the computer with a USB cable 

the  unit  will  recharge  the  AA  batteries  inside  the  unit.  This  recharge  method  is  usually  slower  than 
recharging  with  a  separate,  dedicated  AA  recharger  but  USB  recharge  is  sufficient  for  keeping  the 
RQ8000 unit measurement ready for occasional measurements. 
The  usual  measurement-recharge  ratio  for  USB  charge  is  20%  vs  80%,  if  the  unit  gets  one  hour  of 
measurement time it should get four hours of USB recharge to get fully recharged. Please check that 
your RQ8000 unit supports USB charging before using this option. 
 

NOTE

:  Because  of  the  USB  charging  function  it  is  extremely  important  that the  batteries  are  always 

correctly aligned and 

only rechargeable AA batteries are used with RQ8000 unit

.  

If  the  batteries  are  not  intended  for  recharging  they  may  overheat  or  even  explode  and  inflict 
serious damage to the RQ8000 unit and its surroundings

Summary of Contents for RQ8000

Page 1: ...RQ8000 Paper Roll Quality Tester Technical Manual...

Page 2: ...State Released Company Proceq SA Ringstrasse 2 CH 8603 Schwerzenbach Switzerland Classification Manual Revision History Rev Date Author Comments 0 8 Sep 27 2020 PEGG Initial document 0 9 Oct 1 2020 DB...

Page 3: ...ing Batteries 5 4 Measurement and Calibration 6 4 1 Performing a measurement 6 4 1 1 Turning the power on and off 6 4 1 2 Using the barcode reader to read a new roll tag 6 4 1 3 Using the barcode butt...

Page 4: ...ns conform to the instruction manual at hand at the time of publishing or printing However Proceq SA policy is one of continuous product development All changes resulting from technical progress modif...

Page 5: ...measuring unit and distance encoder Paper reels with non uniform hardness profile may cause problems when printed or converted RQ8000 is the fastest and the most accurate system to detect reels that n...

Page 6: ...27 October 2020 Copyright 2020 PROCEQ SA 2 2 System Parts 2 1 RQ8000 measurement system Each RS8000 Roll Quality Measurement system comes with a sturdy padded carrying case containing...

Page 7: ...measurement device 4 4 Rechargeable AA batteries preferably removed from the RQP before packing 1 Battery charger power cord 1 Car power adapter 1 SD Card 1 USB cable type A B 1 USB memory stick with...

Page 8: ...eries due to the unit s built in recharging function Reliable measurement requires that the NiMH batteries are in good condition and that the capacity of the batteries should preferably be 2000mAh or...

Page 9: ...nd the timestamps of the measured files are correct 3 2 2 Recharging Batteries There are two methods of keeping RQ8000 batteries loaded and ready for measurement Every RQ8000 unit is supplied with an...

Page 10: ...barcode button to create a new roll tag from scratch If the measured rolls do not have barcode IDs but you wish to create a marker to separate your measurements from each other for different rolls fo...

Page 11: ...sure When performing a calibration sample measurement the movement speed should be closer to 1cm per second For optimal results the calibration sample is measured twice without lifting the unit from t...

Page 12: ...hat comes with the RQ8000 unit 5 1 File Management The RQ8000 installation program registers the roll file types so that they can be manipulated directly from the Windows Explorer When the RQ8000 soft...

Page 13: ...iew Component window s 5 2 1 Builder Builder has an user interface including Build path control Any changes on path will start build action of the directory Build path may be selected using standard w...

Page 14: ...27 October 2020 Copyright 2020 PROCEQ SA 10 Recent Builds shows a history and user defined permanent build paths enabling quick browsing of latest measurements...

Page 15: ...2 View Component 5 2 3 Main Control and Settings Clicking on the Main Control window Settings button opens up the Settings dialog Double click on the desired setting change or right click to select i...

Page 16: ...27 October 2020 Copyright 2020 PROCEQ SA 12 Click on the setting and select the value from drop down menu or type in the numeric value Verify the value and click OK or CANCEL...

Page 17: ...changed value is marked with an asterisk and also the heading has one if any of the settings is changed from the last applied one Apply the setting with APPLY or OK If you would like to cancel the set...

Page 18: ...der Built in camera with illumination various formats supported including linear stacked linear and matrix bar QR codes range 1 30cm Battery Type 4 x AA flight safe batteries rechargeable Capacity 250...

Page 19: ...onopolis Way 20 02 Connexis South Tower 138632 Singapore 65 6382 3966 info asia proceq com PROCEQ RUS LLC Ul Optikov 4 korp 2 lit A Office 410 197374 St Petersburg Russia 7 812 448 35 00 info russia p...

Reviews: