    Locate the Door Controller or manually add it to the list.

a.  If you have just one door controller, it should be found automatically.
b.  If you have more than one, choose the one this computer will use.
c.  If it is not found, manually type the IP address and choose Add to List.    

  Or, choose Edit to display an on-screen keyboard (use a period to 

  separate octets, like 192.168.0.25) and then choose Add to List.
d. 

Optional: 

The Advanced button should only be used to change the  

 

  name or set a static IP address for the selected device. If you have more   

  than one door controller, changing the name may be helpful to identify 

  the location, such as “FRONT DR,” “BACK DR,” etc.

6

    Test and select the device.

a. With the proper Door Controller highlighted on screen, click Test to send 

  a signal to the controller. The green light on the side of the controller 

  should come on for just a moment.

b. Click Select to choose this device and return to the Hardware screen.

7

  At the Hardware screen:

a. Set the Delay (time to wait before the door opens) and Duration  

  (time you’d like the door to stay open).
b. Click the Test button to confirm the door opens. Your door circuit must 

  be attached to the Door Controller and both the door strike and 

  controller unit must have power.
c. Check the box next to Authorized Pick Up and/or Employee if you wish  

  to require a person to check in/out in order to open the door.

 

Explanation: For staff, you would often leave this unchecked, so they could 

  open the door as needed throughout the day, without having to actually  

  check in or out. Search ProcareSupport.com for faq147.

8

    Close out of the hardware and check-in settings.

a. Choose Exit to leave the Hardware screen and Exit again at the  

  Check-In Options (School Info) screen.
b. To close the main check-in screen, dbl-click in the gray border area 

  around the logo (or press Esc on your keyboard) and then click Exit.

Check-In Computer Settings & Test

Summary of Contents for Network Door Controller

Page 1: ... of the pickup person In this case a check in computer is not necessary Settings for the Door Controller are accessed from your Procare Home screen For detailed instructions search ProcareSupport com for the following articles Install on a check in computer article KB0495 Special instructions for a Procare Touch computer article KB0911 Receptionist check in feature article KB0163 CONNECTIONS SETTI...

Page 2: ...ied a Attach one wire from the Door Strike circuit to the Common C terminal as shown in diagram A b Attach the other wire to For an electric door strike Connect to the Normally Open NO terminal as shown in diagram A For a magnetic lock Connect to the Normally Closed NC terminal Note Diagram A shows a NO connection Change to a NC connection for a mag lock NOTE A manual bypass is strongly recommende...

Page 3: ...omputer dbl click the Procare Check In shortcut on your desktop 2 Dbl click in the gray border area around the logo or press Esc on your keyboard and then click Options 3 Click the Hardware button right side 4 Choose Network as the type of door controller and click Select Check In Computer Settings Test ...

Page 4: ... on the side of the controller should come on for just a moment b Click Select to choose this device and return to the Hardware screen 7 At the Hardware screen a Set the Delay time to wait before the door opens and Duration time you d like the door to stay open b Click the Test button to confirm the door opens Your door circuit must be attached to the Door Controller and both the door strike and c...

Page 5: ...3 Uncheck Not Using a Door Controller and then click Choose a Device 4 Locate the Door Controller or manually add it to the list a If you have just one door controller it should be found automatically b If you have more than one choose the one this computer will use c If it is not found manually type the IP address and choose Add to List d Optional The Advanced button should only be used to change...

Page 6: ...like the door to stay open b Click the Test button to confirm the door opens Your door circuit must be attached to the Door Controller and both the door strike and controller unit must have power 7 Click Save Exit Receptionist Settings Test Optional A front desk person uses the Receptionist method to check children in on behalf of the pickup person Buzz Door Open using the Receptionist a From the ...

Reviews: