Operation
17 / 24
5310.0375
V3
GB
●
The device is hanging a little angular (incline). Move with the support profile against the outer surface of
the long blade (of the
L-stone
) and set the device (
WEZ
) down centric.
see Fig. C
●
When lifting the first gripping good (
L-stone
) check, if the gripping good is hanging vertical (or rather
maximum 10°
diagonally
) and that the support plate (8) rests on the gripping good (
L-stone
)
Fig. D
●
IMPORTANT:
When gripping and the following lifting and transportation of the gripping good the lifting
eye (1) must be in the
front
position of the suspension (2).
(
Fig. D, Fig. E1 and E2
).
●
According to the position, the suspension (2) must be moved in another position.
Therefore remove the two socket pins (B), move the suspension (2) to another position at the
supporting arm (3) and insert the two socket pins (B) again.
So that the device is hanging almost
vertically
in any case of when lifting and transportation.
●
While lifting, the gripping good (L-stone) should
not
hang
diagonally
(more than
10°
). Otherwise the
gripping good (L-stone) could fall down (
Danger to life!
) and the device is irregular loaded (
risk of
fracture!
)
●
Set the gripping good down on the ground, the device (
WEZ
) opens automatically, the
automatic release
locks it into position so that the device can be lifted without closing up.
Placed the device over the next gripping good, the
automatic release
disengages itself and the gripping
good can be lifted, if the supporting arm (3) is moved down completely.
Fig. C
Fig. D