Adjustment pan profile
Loosen both nuts (2) on the inner side at the TAS-DP.
Figure 7
Adjust the slope (e.g. 1%) with the both nuts (3) on the inner side at the TAS-DP.
Figure 8
Slope (e.g. 1%) is viewable and adjustable on the scale (4) and indicator (5).
Figure 9
1 scale line on the scale (4)
≙
0,5 % slope.
Figure 9
The indicated slope (%) on the scale is only for orientation.
The actually slope (%) must be measured again unconditional on the facing bedding sand!
See Figure
B
und B1 on the following pages.
Figure 7
Figure 8
Figure 9
Measure the outer dimension at the TAS-DP (1) with a qualified measuring tool (6) e.g. yard stick (or slide gauge). These
measure must be equal at the front side and back side (see
).
Figure 10
and
Figure 11
.
Tighten both nuts again (tight) on the inner side at the TAS-DP.