![probst SVZ-UNI Series Operating Instructions Manual Download Page 53](http://html1.mh-extra.com/html/probst/svz-uni-series/svz-uni-series_operating-instructions-manual_1608388053.webp)
Maintenance and care
21 / 25
7
Maintenance and care
7.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed in the
maintenance interval.
Used
only original spare parts
, otherwise the warranty expires.
All operations
may only be made in closed state of the device!
For all operations you have to make sure, that the device will not close unintended. Danger of injury!!!
Service interval
Maintenance work
First inspection after
25 operating hours
●
Control and tighten all screws and connection.
(The implementation is only allowed by an expert).
All 50 operating hours:
●
Tighten all screws and connection (Take care that the tightening torques
according to the property class of the screws are observed).
Minimum 1x per year
(at rough conditions shorten
the interval)
●
Check of all the suspension parts, bolts and straps. Check for corrosion and
safety by an expert.
Before each start-up:
●
Check all brackets for mobility, abrasion and contamination.
Worn (no longer sharp-edged) or bent brackets
must
be replaced!
Regular:
●
Cleaning of the device with high pressure cleaner (warm water), when dirty.
Weekly:
●
Lubricate and oil mobile parts (see arrows in Fig. 1, 2).
Monthly:
●
Check screws and nuts for tightness.
Fig. 1
Fig. 2