Maintenance and care
13 / 15
5480.0002
V5
GB
5
Maintenance and care
5.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Used
only original spare parts
, otherwise the warranty expires.
All operations
may only be made in closed state of the device!
5.1.1
Mechanical
SERVICE INTERVAL
Maintenance work
First inspection after
25 operating hours
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
All 50 operating hours
Tighten all screws and connections (take care that the tightening torques according to
the property class of the screws are observed).
Check all existing safety elements (such as linchpins) for perfect function and replace
defective safety elements.
1)
Check all joints, bolts, guidance’s and gears for correct function, if necessary adjust or
replace it.
Check all grippers (if available) for signs of wear.
Grease all slidings (if available) when the device is in opened position with a spatula.
Grease all grease nipples (if available) with a grease gun.
Minimum 1x per year
(at rough conditions shorten the
interval)
Check of all the suspension parts, bolts and straps. Check for corrosion and safety by an
expert.
1)
5.2
Repairs
Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by an expert.