Maintenance and care
HVZ-uni
V7
18/06/12
32 / 36
8
Maintenance and care
8.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Attention
Take care that for all maintenance services the device is completely shut down!!
MECHNICAL
Service interval
Maintenance work
First inspection after
25 operating hours
●
Control and tighten all screws and connection.
(The implementation is only allowed by an expert).
After 50 operating hours
●
Tighten all screws and connection (Take care that the tightening torques
according to the property class of the screws are observed).
●
Check all joints, bolts, guidance’s and gears for correct function, if
necessary adjust or replace it.
●
Check all Grippers ( if available) for signs of wear.
●
Grease all slidings ( if available) when the device is in opened position
with a spatula.
Minimum 1x per year
(at rough conditions
shorten the interval)
●
Check of all the suspension parts, bolts and straps. Check for corrosion
and safety by an expert.
LUBRICATION SIDE CLAMPING
Grease the side clamping in the area of the plastic
bushing if required with spray-lubrication (with PTFE)
see arrows.