background image

2.3 OPERATION 

 

 

WORK / OFF / MOVE Toggle Switch (SW2) 

WORK

Enable the system in “WORK procedure” standby. Press/release the footswitch to start “WORK 

procedure”. Faceplate rotates according to parameter setting (RPM and welding angle) 

OFF

Reset error and stop work procedure.   

MOVE

Enable the system in “MOVE” procedure standby. Press the footswitch to start the rotation, and 

release footswitch to stop the rotation. Rotation speed varies according to parameter 

 

NORMAL / RAPID Toggle Switch (SW3) 

NORMAL

Faceplate rotation speed varies according RPM setting. 

RAPID

Faceplate rotates with maximum speed. 

 

WELD / TEST Toggle Switch (SW4) 

WELD

Welder output (P2) will be enabled when faceplate start rotating in either WORK or MOVE (SW2) 

procedure. 

TEST

Welder output (P2) is disable in WORK/MOVE procedure. 

Note

Welder output (P2) Type

Relay dry contact.   

 

STOP Button

 

Press to stop the all control. Rotate CW/Pull to reset. 

 

Homing Sequence (Option)

 

Homing sequence activates automatically when below condition are met. 
A.  Right after placing WORK / MOVE toggle switch (SW2) in WORK position. 
B.  2 seconds after end of “WORK procedure”. 
C.  Flipping Forward/Reverse (SW1) switch in “WORK procedure” standby. 

D.  Reset the STOP button in “WORK procedure” standby. 

Note

Homing sequence is divided into 2 stages. Faceplate first rotates in half of maximum speed until 
home sensor is triggered and stops. Then faceplate rotates according to RPM rotation speed 
setting to trigger the home sensor again. Problem may rise in second stage when RPM rotation 
speed is adjusted too small.   

Warning

Homing sequence is a semi-automatic process that activates when above conditions 

are met. Operator caution is advised. 

 

Summary of Contents for PT-502

Page 1: ...ACCESSORIES MODEL PT 502 PT 502M DIGITAL WELDING POSITIONER Serial Number 202003 and later Revised Date Feb 24th 2020 UNITED PROARC CORPORATION No 3 Gungye 10th Road Pingjen Ind Park Tel No 886 3 4696...

Page 2: ......

Page 3: ...nty iii 1 1 Introduction 1 1 2 Specifications 2 2 1 Control panel 3 2 2 Installation 4 2 3 Operation 5 2 4 Display operation 7 2 5 Timing diagram 8 3 1 Maintenance 9 3 2 Troubleshooting guide 11 4 1 P...

Page 4: ...hipping documents Make sure it is complete and inspect the equipment for possible damage during shipping If there is any damage notify the carrier immediately to file a claim Furnish complete informat...

Page 5: ...ral wire Interventions Before control and repair see the apparatus is switched off and insulated Connection with fixed installation cable is impossible It s on Stop and connection is impossible Some a...

Page 6: ...n to repair or replacement of a defected part under this warranty shall be based on FOB Taiwan basis The warranty period begins on the date of sale to the original purchase user of the equipment UNITE...

Page 7: ...T T TH H HI I IS S S P P PA A AG G GE E E I I IS S S B B BL L LA A AN N NK K K...

Page 8: ...u require The table can be tilted for 0 135 which is convenient for all angles of the pipe welding or for adjusting welding angles It can adopt either manual or electrical operation The table has a th...

Page 9: ...rizontal kg 500 Rated Centre of gravity mm 200 Rated eccentricity mm 100 Table diameter mm 450 Rotation speed rpm 0 12 2 0 Spindle thru hole mm 25 Earthing Amp 200A Max 400A Tilt range deg 0 135 Weldi...

Page 10: ...n 4 Power switch PSW 5 CW CCW selection switch SW1 6 Power On signal LED 7 Weld Test mode selection switch SW4 8 Weld Rapid speed selection switch SW3 9 Auto OFF Move mode selection switch SW2 10 Powe...

Page 11: ...rotation to lock counter clockwise rotation to release Danger Do not release the tilt handle when part is loaded on the faceplate PSW Power Switch I On O Off LED Indicator Color Identification Green S...

Page 12: ...T Welder output P2 is disable in WORK MOVE procedure Note Welder output P2 Type Relay dry contact STOP Button Press to stop the all control Rotate CW Pull to reset Homing Sequence Option Homing sequen...

Page 13: ...rotation speed Example1 Set weld speed knob 100 and external variable foot switch 50 the resulting rotation speed is 100 x 50 50 Example2 Set weld speed knob 50 and external variable foot switch 50 th...

Page 14: ...ch and set parameters Rotate to change and modify display After modifying the speed the operator is required to step press the footswitch to save the parameter The parameter is default to last value i...

Page 15: ...8 2 5 TIMING DIAGRAM CB 104D With SENSOR CB 104D HOMING SEQUENCE...

Page 16: ...To make the machine run normally the control box the machine and the table should be kept clean all the time Check at any time the lubrication of the reducer to extend the lifetime of the machine Che...

Page 17: ...10 T T TH H HI I IS S S P P PA A AG G GE E E I I IS S S B B BL L LA A AN N NK K K...

Page 18: ...itch Step on the footswitch and use an ohmmeter to measure footswitch connector pin4 and pin5 The reading should be 0 short circuit Replace the footswitch when necessary D Inspect Control Board JP2 fo...

Page 19: ...hing and there is no rotation place the Work Move switch SW2 in Move position and adjust the rotation speed setting to desired speed Restart the homing sequence C Proximity switch too far Adjust the p...

Page 20: ...1 14 5014 2220000 31 Tilting drive pinion 1 15 5014 2210001 30 Drive pinion 1 16 0353 0318 Worm reducer 1 PT 502 0351 0131 Gear reducer 1 PT 502 0361 1005 9 PMDC motor with cable 1 PT 502 17 5015 210...

Page 21: ...14 4 1 PARTS LIST MACHANISM...

Page 22: ...Remark 1 5010 2050102 10 Carbon brush 1 2 0144 0028 Spring 2 3 5010 2040400 10 PE plastic body 1 4 0106 0805 Hex cap screws cupper 1 5 0121 0804 Washer cupper 2 6 4000 274859 Terminal 1 7 0123 0802 N...

Page 23: ...622 1010 Printed circuit board 1 Switch board 5 6651 1010 Printed circuit board 1 With PT 502 6 3328 0008 Power supply 1 7 6651 1310 Printed circuit board 1 Motor speed control 8 3545 5001 Grounding c...

Page 24: ...17 5 1 MAIN CIRCUIT...

Page 25: ...18 5 2 MOTOR SPEED CONTROL BOARD TILTING PT 502...

Reviews: