ProArc 15062500401 Owner'S Manual Download Page 9

 

2.1 TROUBLE SHOOTING GUIDE 

 

SYMPTOMS

 

POSSIBLE CAUSES

REMEDIES

 

Forward / Reverse 
revolutions not functioning 
correctly. 

A. Footswitch is damaged

 

(1)  Measure footswitch connector Pin 1&2, step on the footswitch and 

measure Pin 1&2 is shorted. if not, replace a new footswitch. 

(2)  Step on the footswitch and check if relay board D11 illuminates, if 

yes ,but has no action, replace a new relay board. 

B. Forward / Reverse revolution switch is damaged

 

(1)  Switch to "Forward" position and check if Relay board D3 

illuminates, if not, please replace the front panel board. 

(2)  Switch to "Reverse" position and check if Relay board D4 

illuminates, if not, please replace the front panel board. 

C. K1 ~ K4 relay is damaged

 

(1)  Switch to "Forward" position and if Relay board D3 illuminates but the 

relay has no action, please replace the relay board. 

(2)  Switch to "Reverse" position and if Relay board D4 illuminates, but the 

relay has no action please replace the relay board. 

Can not adjust speed. 

A. Motor control PCB is damaged

 

(1)  Check the motor control PCB. It should have an input voltage of 

30VDC between DC+ & DC-. 

(2)  Adjustment weld speed, measure A1 & A2, it should read approx. 

6.5VDC, if not, voltage replace the motor control PCB. 

B. Weld / Speed switch is damaged (Weld /Full speed)

 

(1)  Switch to Manual mode and adjust the weld speed dial to about 50% 

of the full speed, then step on the footswitch. 

(2)  Switch to both weld and speed positions, the motor should respond 

with slow and fast speeds respectively, if not then replace a new front 
panel board. 

C. The potentiometer is damaged

 

(1)  Detach the Front panel board CN2 connector, use ohmmeter to 

measure Pin 1 & 2. 

(2)  Rotate the weld speed variable resistor's and check if the resistance 

value is changing. If not, please replace VR1. 

Weld timer not functioning 

A. T1 Timer is damaged

 

(1)  Switch to "Auto" position and step on the footswitch. 
(2)  CheckT1 the motion window of the timer, the "UP" signal should lit, if 

not, please replace relay board. 

B. T1 The Timer is unable to stop

 

(1)  Detach the Relay board J1 connector, measure Pin 1&2. 
(2)  T

 

Rotate the timer knob and see if the resistance between Pin 1&2 is 

changing from 0~1M ohm. If not, please replace the VR2 (Timer 
knob). 

 

Summary of Contents for 15062500401

Page 1: ... CB 001 STANDARD CONTROL BOX Serial Number 15062500401 and later Revised date July 13th 2015 UNITED PROARC CORPORATION No 3 Gungye 10 th Road Pingjen Industrial Park Tel No 886 3 469 6600 Pingjen City Taoyuan 324 Taiwan Fax No 886 3 469 4499 http www proarc com tw E Mail customerservice proarc com tw RD 886GE ...

Page 2: ......

Page 3: ... Operator controls Trouble shooting Parts list Circuit diagram Revision Limited warranty i 1 Control panel 1 2 Trouble shooting guide 3 3 1 Control box front 5 3 2 Control box rear 6 4 1 Control system 7 Wiring diagram 8 Revisions 9 ...

Page 4: ...air at its option of the defected part only ProArc s option to repair or replacement of a defected part under this warranty shall be based on FOB Taiwan basis UNITED PROARC CORPORATION shall not be liable for any loss or consequential damage or express accruing directly or indirectly from the use of equipment covered by this warranty This warranty supersedes all previous ProArc warranties and is e...

Page 5: ...T T TH H HI I IS S S P P PA A AG G GE E E I I IS S S B B BL L LA A AN N NK K K i ...

Page 6: ...Auto Manual mode selection switch S 4 Clockwise counter clockwise selection switch S 5 Weld rapid speed selection switch VR1 Welding speed adjustment VR2 Welding timer adjustment Rear Panel SW1 Power switch SW2 Voltage selection switch F1 Fuse 1A CM1 Motor connector 2Pin CM3 Foot switch connector 3Pin CM4 Welding source connector 4Pin 1 ...

Page 7: ...tch Automatic AUTO The start of the rotation is activated by the foot switch the duration of the rotation and is controlled by the TIMER knob on the front panel from for a duration of 0 60 second 4 S4 Direction switch select the direction of rotation clockwise or counterclockwise 5 S5 WELD RAPID Switch select the operating Welding speed WELD Turn table rotation speed can be adjusted from WELD SPEE...

Page 8: ... the flat cable F PB1 is damaged Keep PB1 pressed and measure front panel PB1 s connection CN1 s Pin 7 8 If no connection replace a new PB1 Motor has no motion A Motor coil is damaged Use ohm meter to measure CM1 female plug pin 1 2 and It should give you 2 ohm If 2 ohm doesn t exist replace the motor B Motor has power input but no motion Measure CM1 male socket Pin 1 2 if there is 6 5VDC then rep...

Page 9: ...s damaged 1 Check the motor control PCB It should have an input voltage of 30VDC between DC DC 2 Adjustment weld speed measure A1 A2 it should read approx 6 5VDC if not voltage replace the motor control PCB B Weld Speed switch is damaged Weld Full speed 1 Switch to Manual mode and adjust the weld speed dial to about 50 of the full speed then step on the footswitch 2 Switch to both weld and speed p...

Page 10: ... Motor speed control board 1 Motor control 3 6621 2240 Front panel board 1 Front panel board 4 3216 0003 Knob Blue 2 Knob 5 3311 0039 Transformer 1 TR 6 3747 1001 Potentiometer 1 VR1 7 3747 1002 Potentiometer 1 VR2 8 3214 2009 E S Push button 1 E Stop 9 3271 3002 8 LED Push button 1 PB1 Recommended spare parts Options 5 ...

Page 11: ...n switch 1 SW2 3 3331 2001 Power entry module 1 SW1 4 3226 2001 Fuse 1A 20mm 2 5 5010 1020020 11 PMDC Motor with connector 1 CM1 Motor connector 6 3242 1101 Foot switch Assy cable 3M 1st Foot switch Assy 7 3445 0001 Power cable 1st Power cable 8 3123 2005 Female connector 4 pin 1 CM4 TH connector Recommended spare parts Options 6 ...

Page 12: ...4 1 CONTROL SYSTEM 7 ...

Page 13: ...4 2 WIRING DIAGRAM 8 ...

Page 14: ...1 P9 P10 Adding E Stop RD 886DE Jul 21 2010 3 1 P7 8 Revised 6651 0001 6651 0011 RD 886DE Jan 03 2011 3 1 P5 Revised 3311 0023 3311 0039 Number 2011 Later RD 886FE Mar 29 2013 3 1 P5 Revised No 1 Relay board 6620 1122 6620 1123 RD 886GE July 7th 2015 Add PB1 control and part list 9 ...

Reviews: