background image

21

30502

30503

30504

General Purpose Clip Sling w/ Padded Legs, Polyester - Medium (MAA4000M-M)

General Purpose Clip Sling w/ Padded Legs, Polyester - Large (MAA4000M-L)

General Purpose Clip Sling w/ Padded Legs, Polyester - XLarge (MAA4000M-XL)

Protekt® All-In-One Slings

Summary of Contents for PROTEKT 33350

Page 1: ...ed according to the instructions in this manual All operators should read and understand the instructions for safe and proper operation of the patient lift PROTEKT ALL IN ONE UNIVERSAL PORTABLE ELECTR...

Page 2: ...wing information for future use Supplier Name ___________________________________________ Supplier Telephone ________________________________________ Product Serial Number ____________________________...

Page 3: ...ional battery pack you will never have to be worried about your lift not being charged and ready for use The 33350 is intended to be used with patients who are completely immobile or totally dependent...

Page 4: ...o physical contact with the pa ent in order for the device to carry out its intended use Do Not Iron Item may not be smoothed or nished with an iron Class II symbol To iden fy equipment is designed th...

Page 5: ...ho are comatose spastic agitated or otherwise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patien...

Page 6: ...ntact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Using accessories detachable parts or materials not described in the instruction manual MAY RESULT IN SERIOUS...

Page 7: ...ld not be put into use until all connections are tightened using standard tools Easy Tools Screwdriver 7 5 lb 3 4 kg 11 lb 5 kg 0 7 lb 0 6 lb 0 3 kg 0 3 kg 8 4 lb 3 8 kg 5 Spreader Bar 6 Rear Caster 1...

Page 8: ...2 68 1 B 1070 8 42 2 C 658 4 25 9 D 492 2 19 4 E 812 8 32 0 F 766 9 30 2 G 576 7 22 7 H 333 3 13 1 I 496 9 19 6 J 275 10 8 K 442 7 17 4 L 118 5 4 7 M 20 3 0 8 N 1170 7 46 1 O 658 7 25 9 P 376 4 14 8 3...

Page 9: ...ht Highest 64 7 1643 mm H Base Opened Turning Diameter 55 7 1414 mm I Base Closed Turning Diameter 51 2 1300 Input Voltage 220 240VAC 50Hz 110 120VAC 60Hz Output Voltage 24 VDC Battery Pack 24 VDC 5AH...

Page 10: ...hole on the stand bracket with the lower hole on the mast Make sure the tab on the stand bracket insert into top hole on the mast and insert the screw to secure the stand bracket as follows Step 3 Re...

Page 11: ...om Step 7 Remove lower actuator pin on the mast Step 8 Move the boom out of the way and install the lower end of the actuator to the mast using a pin and retaining ring as follows It is critical to ha...

Page 12: ...d of actuator to the boom by reinserting the quick release pin to secure it Step 10 Insert the spreader bar into the tube on the boom as follows Align the holes and secure the spreader bar using a pin...

Page 13: ...12 4 3 2 1 5 M5 SCREWS M4 SCREWS...

Page 14: ...Step 1 Remove The Spreader Bar WARNING Step 2 Detach The Actuator 13 1 2 1 2 13...

Page 15: ...Step 3 Fold Up The Boom Step 4 Fold Up The Mast 14 1 2 3 1 2 3...

Page 16: ...Standing Up Lying Down 15...

Page 17: ...octor nurse or medical attendant select a sling that is both practical and comfortable The sling selected should be one that serves the needs of the patient while providing the patient with optimal sa...

Page 18: ...cord that may cause strangulation if used improperly Keep long charger cord out of walkway where it poses a tripping hazard Have the charger port on the controller facing away from the wall for easy...

Page 19: ...g charging the LCD Display Panel will show one of the four signs below The DC Charger must be connected The emergency stop button must be released The battery will not be charged if the emergency butt...

Page 20: ...LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel 19...

Page 21: ...play Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery needs to be charg...

Page 22: ...l Purpose Clip Sling w Padded Legs Polyester Medium MAA4000M M General Purpose Clip Sling w Padded Legs Polyester Large MAA4000M L General Purpose Clip Sling w Padded Legs Polyester XLarge MAA4000M XL...

Page 23: ...oint 4 Hook up D 1 3 2 4 B A C D 22 dealer Slide the clip over the sling hook on the spreader bar through the hole Pull down the clip to lock the sling on to the spreader bar Sling Hook Sling Clip EAC...

Page 24: ...edures when returning the user patient to bed 1 Help the user lean forward slightly then slide the sling down between the chair and the user s back 2 Position the commode aperture where the buttocks m...

Page 25: ...re positioned midway under the thighs to provide good support and greater comfort 8 Position the boom to the proper height to extend the spreader bar into the car without hurting the patient or the ca...

Page 26: ...rior to use for the additi inspection interval and the visual inspection points are listed below Note Bestcare assumes that the assembly instructions were performed properly and by a qualified individ...

Page 27: ...ent uses we recommend wipes with water soluble soap or isopropyl alcohol For slings with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for remov...

Page 28: ...n usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside the...

Page 29: ...the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair wise continually until the patient has been lowered NOTE THE EMERGENC...

Page 30: ...WARRANTY POLICY All In One 29...

Page 31: ...com...