Pro1 Technologies T855iSH Installation Manual Download Page 1

T855iSH

Installation Manual

Pro1 Technologies

Toll Free: 888-776-1427 

Web: www.pro1iaq.com

Hours of Operation: M-F 9AM - 6PM Eastern

 

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes

Yes
Yes
Yes
Yes

No

Power Type

Hardwire (Common Wire)

Table of Contents

Installation Tips

Thermostat Quick Reference

Wiring

Wiring Diagrams

Technician Setup Menu

WIFI Tech Settings

Setting Humidity

Programming

Features 

Remote Sensor Operation

Specifications

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en espanol de este 

manual se puede descargar en 

la pagina web de la compania.

Rev.  2028

     U.S. Registered Trademark. Patents pending

Copyright      2020 All Rights Reserved.

5-8

15-33

1

2-4

Yes
Yes

34

Mount Thermostat

Align the 4 tabs on the subbase with 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps in place.

Installation Tips

2

Note:

 To ensure a solid fit between the 

thermostat and the subbase:

1. 

Mount subbase to a flat wall

2.

 Use screws provided

3.

 Drywall anchors should be flush with the wall

4.

 Wires should be pushed into the wall

Installation Tips

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind the thermostat

•  In areas that do not require conditioning

•  Where there are dead spots or drafts (in corners or behind doors)

•  Where there might be concealed chimneys or pipes

Wall Locations

Pick an installation location that is easy for the user to access.  The temperature 

of the location should be representative of the building.

Installation Tip

Do not install thermostat in these locations:

3

4

Installation Tips

35-37

Vertical Mount

Horizontal Mount

For horizontal mount put one screw on 
the left and one screw on the right.

All of our products are mercury free. However, if the product you are 

replacing contains mercury, dispose of it properly.  Your local waste 

management authority can give you instructions on recycling and 

proper disposal.

Mercury Notice

Failure to disconnect the power before beginning to install this product 

can cause electrical shock or equipment damage.

Installation Tip: Electrical Hazard

For vertical mount put one screw on 
the top and one screw on the bottom.

Subbase Installation

11-14

9-10

Wired Remote Sensing

Yes

P.O. Box 3377
Springfield, MO 65808-3377

Any HVAC system up to 5H/3C with 

standard low voltage controlled humidifier.
Any HVAC system up to 5H/3C with standard 

low voltage controlled de-humidifier.

Yes

Yes

44

45

38-43

46

Summary of Contents for T855iSH

Page 1: ...all 4 Wires should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulati...

Page 2: ...e the bevel on lower ridge Day of theWeek Setpoint Indicator Displays the user selectable setpoint temperature Energy Efficient Globe Indicates the setpoint temperature chosen is a efficient choice In...

Page 3: ...gency heat relay a jumper can be installed between E and W2 to turn thermostat into a single stage control for Emergency Heat Operation 9 10 11 12 Wiring Diagrams Wiring Diagrams Typical2H 2CSystem 1T...

Page 4: ...nd stage will turn on at 2x the swing setting The second stage will turn off when 1x the swing is reached For example if the swing setting is 5 degrees for heating and the thermostat is set at 70 F th...

Page 5: ...pump applications OF DUAL FUEL Use the and buttons to select ON OFF SET STAGES 2H2C PROGRAM 7d 4 TIME PERIODS PRO RECOVERY This setting maximizes efficiency and equipment longevity by increasing the h...

Page 6: ...iods is set to 2C or 4C Use the and buttons to adjust Pre Occupancy Fan Youcanselectthe pre occupancyfanfromOFF 1 2 or3hours If1 2 or3 isselected thefanwillturn onthatmanyhourspriorto thescheduledoccu...

Page 7: ...lect OFF 10 15 20 25 30 35 40 45 50 degrees OFF BALANCE POINT OF Balance point with electric auxiliary will optimize heat pump usage When the outdoor temperature is above the AUX CUT OUT selection the...

Page 8: ...an explanation of these options 1 1 DUM Terminal Onlyshowsif dehumidifyis setto ON DUM TERMINAL HUM Terminal DHM Terminal OPTIONS 1 2 3 4 HUM terminal energizes when the ambient humidity is Below the...

Page 9: ...64 6 65 4 66 4 67 4 68 2 68 2 68 9 69 2 65 3 66 2 67 2 68 2 69 1 69 1 70 70 1 66 67 68 69 70 70 71 71 67 2 68 2 69 1 70 1 71 1 71 4 72 4 72 6 68 3 69 3 70 3 71 3 72 3 72 8 73 8 74 3 69 7 70 7 71 7 72...

Page 10: ...ng 1 Select HEAT or COOL with the SYSTEM key Note You have to program heat and cool each separately 2 Press the MENU button If menu does not appear first press RUN SCHED 3 Press SET SCHED Note Monday...

Page 11: ...F 17 C 70 F 21 C 62 F 17 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C Programming Factory Default Program for 2 Time Period...

Page 12: ...g 802 11 B G N Standards 45 46 Specifications Remote Sensor Operation Option 1 Indoor Local Temperature Sensor ON 1 The displayed room temperature will display the average temperature of the thermosta...

Reviews: