background image

7

TECHNICIAN SETUP MENU

TECH SETUP

STEPS CONTINUED

ON THE NEXT PAGE

Use the         or 

key to select the 

maximum heat 

setpoint.    

90 ºF

Adjustment Options

Factory Default Settings

This feature 

allows you to set a 

maximum heat 

setpoint value. 

The setpoint 

temperature 

cannot be raised 

above this value.

Tech Setup Steps (Continued from the previous page)

Heating 

Temperature 

Setpoint Limit

GAS

or

ELEC

GAS

Select 

GAS

 for 

systems that control 

the fan during a call 

for heat. 

Select 

ELEC 

to have 

the thermostat 

control the fan during 

a call for heat.

Fan

Operation

LCD Will Show

Use the         or 

key to select the 

minmum cool 

setpoint.    

44 ºF

This feature 

allows you to set a 

minimum cool 

setpoint value. 

The setpoint 

temperature 

cannot be lowered 

below this value.

Cooling

Temperature 

Setpoint Limit

Use the         or 

key to select 12 or 24 

hour clock.

12 Hour Clock

You can select 

either a 

12

 or 

24

 

hour clock setting.

12 or 24

Hour Clock

Use the         or 

key to turn on or off.

ON

This feature turns your 

system on before the 

WAKE

 programming 

time to ensure the 

enviroment is at the 

WAKE

 setpoint when 

the 

WAKE

 time period 

begins. This recovery 

changes over time 

based on the previous 

days experience.

Morning

Recovery

Use the         or 

key to select 

7d 

for 7 

day, 

5d

 for 5+1+1, 

or 

0d

 for 

nonprogammable.

5d

You can configure this 

thermostat to have a 

7 day program, a 

5+1+1 program or 

nonprogrammable.

Program

Options

Select 

F

 for 

Fahrenheit 

temperature read 

out or select 

C

 for 

Celsius read out

ºF for Fahrenheit

ºC for Celsius

ºF

ºF or ºC

The second stage will turn on at 2x the swing setting. The second stage will turn off when 1x the 

swing is reached. For example, if the swing setting is .8 degrees for heating and the thermostat is 

set at 70ºF, the first stage will turn on at approximately 69.2ºF. The second stage will turn on at 

68.4ºF. The second stage will turn off at 69.2ºF and the first will turn off at 70.8ºF. If third stage is 

used, it will turn on at 3x the swing and turn off at approximately 2x the swing.

PRO1 Tip

Summary of Contents for Toptech TT-S-855

Page 1: ...mmon Wire with Battery Backup Power Type 1 n o i t p i r c s e D Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Multi stage Systems Heat Only Systems Heat Only Systems Cool Only Systems Millivolt Yes Yes Yes Yes Yes Yes Yes Yes Yes Rev 0950 Una versión española de este manual puede ser descargada en www pro1iaq com U S Registered Trademark ...

Page 2: ... are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Where appliances could radiate heat Pick an installation location that is easy for the user to access The temperature of the location should be representative of the building Wal...

Page 3: ...isplayed when thermostat program is permanently overridden 1 will appear in the display when second stage of heat or cool is on 2 will appear for third stage of heat System operation indicators The COOL HEAT or FAN icon will display when the COOL HEAT or FAN is on NOTE The compressor delay feature is active if these icons are flashing The compressor will not turn on until the 5 minute delay has el...

Page 4: ...oducts are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and proper disposal Horizontal mount Horizontal mount Vertical mount Vertical mount For vertical mount put one screw top and one screw bottom For horizontal mount put one screw left and one screw right C O B W E W2 R G...

Page 5: ...ergized in cooling Fan relay Emergency heat relay First stage of heat cool Second stage of cool second stage of heat Auxiliary heat relay third stage of heat This thermostat is shipped from the factory to operate a conventional heating and cooling system This thermostat will also operate a heat pump system See the heat pump configuration step on page 8 of this manual to configure the thermostat fo...

Page 6: ...s and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable from 0 4 F to 2 F For example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint Pick PA or FU P...

Page 7: ... or 24 Hour Clock Use the or key to turn on or off ON This feature turns your system on before the WAKE programming time to ensure the enviroment is at the WAKE setpoint when the WAKE time period begins This recovery changes over time based on the previous days experience Morning Recovery Use the or key to select 7d for 7 day 5d for 5 1 1 or 0d for nonprogammable 5d You can configure this thermost...

Page 8: ... one character to another See note below on operation If selected on you will see the input screen after pressing next step Note If Contractor Call Number is selected ON your phone number will show in the display if there has been a continuous call for heating or cooling for 24 hours or if the light button is held down for 3 seconds To remove the phone number from the display hold the light button...

Page 9: ...LLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert 2 AA Alkaline batteries included ...

Page 10: ...ing Use the or key to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key to select the current hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT STEP Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6 7 8 All programmable Pro1 thermostats are shipped with an en...

Page 11: ...time period Note If you want the fan to run continuously during this time period select ON with the FAN key Press NEXT STEP The setpoint temperature is flashing Use the or key to make your setpoint selection for the weekday WAKE period Press NEXT STEP Repeat steps 4 through 7 for weekday LEAVE time period for weekday RETURN time period and for weekday SLEEP time period Repeat steps 4 through 7 for...

Page 12: ...STEP Repeat steps 4 thru 7 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period PROGRAMMING THE THERMOSTAT 12 1 2 3 4 5 6 7 8 Monday Repeat steps 4 thru 7 for the remaining days of the week Tuesday Wednesday Thursday Friday Saturday Sunday A Note About Auto Changeover Auto changeover will switch between heating and cooling as needed It is very important to ma...

Page 13: ...s adjustable from 0 4ºF to 2 0ºF Cooling is adjustable from 0 4ºF to 2 0ºF 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline Energizer batteries 32ºF to 105ºF 0º to 41ºC 90 non condensing maximum 4 7 W x 4 4 H x 1 1 D 13 SPECIFICATIONS CONTACT INFORMATION Specifications Pro1 IAQ Inc 1111 S Glenstone Suite 2 100 Springfield MO 65804 Toll free 1 888 Pro1iaq...

Reviews: