10. GOOD SAFETY HABITS: 

 

DEVELOP AND PRACTICE A PLAN OF ESCAPE:

 

v

  Make a floor plan indicating all doors and windows and at least two (2) escape 

routes from each room. Second story windows may need a rope or chain ladder. 

v

  Have a family meeting  to  discuss your escape plan, and show everyone what to do 

in case an alarm sounds. 

v

  Determine a place outside your home where you can all meet if an alarm occurs. 

v

  Familiarize everyone with the sound of the Alarm and train them to leave  the  home 

when they hear it. 

v

  Practice a CO / fire drill at least once every six months.  Practice allows you to test 

your plan before an emergency. You may not be able to reach your children.  

It is 

important they know what to do.

 

 
 

WHAT TO DO WHEN THE ALARM SOUNDS: 

v

  See Section 2. 

 

11. SERVICE AND WARRANTY:

 

IMPORTANT! SAFETY INSTRUCTIONS

:

 

 

In the event of any trouble  with  the unit.    Do not attempt to repair the unit,  this 

product should be serviced by  a  qualified service  technician.  Disconnect the battery 
from  the unit and return the unit for servicing to the  appropriate  address  listed on the 
last page of this manual. 
 

Ultralife U9VL-J 9-Volt 5-year Lithium Battery Returns:

 

 

To return a defective Ultralife 5-year lithium battery under warranty, return  the battery, a 
note describing the nature of the difficulty, with proof of date of alarm purchase, postage 
and return postage prepaid to: 

 

 
c/o Ultralife Batteries Inc. 
2000 Technology Parkway 
Newark, New York 14513 

 

 
 

 

This battery warranty is void if the CO alarm or battery have been opened, damaged, 
modified, abused or altered in any way after the date of purchase, or if it fails to operate 
due to improper maintenance, or usage outside the temperature range of 40

o

F (4.4°C) 

to 100

o

F (37.8°C). 

Summary of Contents for 7030

Page 1: ...OXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE GAS FROM ANY SOURCE OF COMBUSTION IT IS NOT DESIGNED TO DETECT SMOKE FIRE OR ANY OTHER GAS CONTENTS OF THIS MANUAL 1 INFORMATION ABOUT CARBON MONOXIDE 2 SPECIFICATIONS 3 RECOMMENDED LOCATIONS OF ALARMS 4 LOCATIONS TO AVOID 5 INSTALLATION INSTRUCTIONS 6 OPERATION AND TESTING 7 FALSE ALARMS 8 MAINTENANCE 9 LIMITATIONS OF CARBON MONOXIDE ALARMS 10 GOO...

Page 2: ...s more tightly to the hemoglobin carboxyhemoglobin COHb than oxygen does When CO combines with hemoglobin the hemoglobin s ability to combine with oxygen is lost As the COHb concentration rises people become nauseous unconscious and ultimately die see below WHAT ARE THE SYMPTOMS OF CARBON MONOXIDE POISONING Many people often confuse carbon monoxide poisoning with the flu the initial symptoms being...

Page 3: ...QUENCY SAMPLES EVERY 2 MINUTES 1 LCD DISPLAY 7035 1 DIGITAL READ OUT OF CO DETECTED AND PEAK LEVEL MEMORY FROM 0 PPM TO 500 PPM WILL FLASH 500 IF LEVEL EXCEEDS 500 PPM 2 PEAK LEVEL TIME RECORD THE TOTAL TIME CO IS DETECTED WITHIN 10 OF THE PEAK LEVEL FROM 0 TO 999 MINUTES WILL FLASH 999 IF LEVEL EXCEEDS 999 MINUTES 3 COHb RANGE CARBOXYHEMOGLOBIN FROM 0 0 TO 99 9 WILL FLASH 99 9 IF LEVEL EXCEEDS 99...

Page 4: ...during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturer s instructions or contact the manufacturers directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in a garage or adjacent to the residence Conditions which can result in...

Page 5: ...easily through the air similar to the scent of perfume dispersing uniformly in all directions This characteristic makes it possible for CO alarms to be mounted anywhere in the room or hallway including both wall and ceiling areas v Locate the first alarm in the immediate area of the bedrooms If more than one sleeping area exists locate additional alarms in each sleeping area v Locate an alarm in e...

Page 6: ...r for the 7030 and 7035 CO alarms is a 9V battery BATTERY INSTALLATION AND REPLACEMENT v Open the battery door to remove the old battery for replacement and install a fresh 9 Volts battery Use Duracell MN1604 or Ultralife U9VLJ only to the battery snap v Press the battery reminder lever down place the battery on top of the lever in the battery compartment and close the battery door WARNING DO NOT ...

Page 7: ...ODEL 7035 To retrieve from memory the CO gas detected press TEST RESET button for a minimum of five seconds The LCD will display the recorded data in the following order 1 The current CO level detected in ppm 2 The peak or highest CO level detected in ppm 3 The total length of time the alarm has detected the peak CO level in minutes and 4 The percentage of carboxyhemoglobin Each reading will appea...

Page 8: ...f the alarm can be wiped with a damp cloth AFTER CLEANING TEST YOUR ALARM BY USING THE TEST BUTTON AND CHECK THAT THE GREEN LED IS ON 9 LIMITATIONS OF CARBON MONOXIDE ALARMS Carbon monoxide alarms are devices that can provide an early warning of the presence of CO gas at a reasonable cost However alarms have sensing limitations and may not always sound a warning in the presence of CO The alarm wil...

Page 9: ... 2 11 SERVICE AND WARRANTY IMPORTANT SAFETY INSTRUCTIONS In the event of any trouble with the unit Do not attempt to repair the unit this product should be serviced by a qualified service technician Disconnect the battery from the unit and return the unit for servicing to the appropriate address listed on the last page of this manual Ultralife U9VL J 9 Volt 5 year Lithium Battery Returns To return...

Page 10: ...under the terms of this limited warranty shall not in any case exceed the cost of the replacement of the CO alarm In no case shall the manufacturer or any of its parent or subsidiary corporations be liable for consequential loss or damages resulting from the failure of the CO alarm to activate or for the breach of this or any other warranty expressed or implied even if the loss or damage is caused...

Reviews: